WTD -70℃~200℃
Special for microchannel/tubular reactor- Heating Power38kW~50kW
- Cooling capacity12kW~50kW
- Circulation fulid50L~60L
- Temperature accuracy±0.3℃
- Temperature resolution0.1K
- Weight2500KG~2600KG
Product data download
Cooling heating and temperature control system (for microchannel/tubular reactor)
It is specially designed and developed for the characteristics of small liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system of the microchannel reactor.
- Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
- Enhance the design of the circulating pump capacity to meet the high pressure drop requirements of the reactor.
- Continuous high temperature cooling technology to meet the requirement of stable operation when the temperature control is required for high temperature exothermic reaction.
Parameters Detailed
Model | WTD-2A38W-2TE2 | WTD-4A38W-2TE2 | WTD-7A50WE2 | |||
Temperature range | -25~200°C | -25~200°C | -45~200°C | -45~200°C | -70~200°C | |
Temperature control accuracy | ±0.5℃ | |||||
Temperature resolution | 0.1K | |||||
Operation panel | Siemens 7-inch color explosion-proof touch screen | |||||
Data curve | Data curve record | |||||
Data output | U disk excel format | |||||
Temperature control accuracy | Guanya Control System Siemens PLC | |||||
System circulating fluid | 30L+30L | 30L+30L | 50L | |||
Expansion tank volume | 120L | 120L | 100L | |||
Heating power | 38KW | 38KW | 38KW | 38KW | 50KW | |
Heater | Leehom heating power 3W/cm2 | |||||
Heating actuator | Voltage regulating actuator 4~20mA control | |||||
Refrigeration ability |
200°C | 38KW | 38KW | 38KW | 38KW | 50KW |
100°C | 38KW | 38KW | 38KW | 38KW | 50KW | |
20°C | 38KW | 38KW | 38KW | 38KW | 50KW | |
-20°C | 15KW | 15KW | 20KW | 20KW | 40KW | |
-35°C | 11KW | 11KW | 25KW | |||
-60°C | 12KW | |||||
Circulating pump max | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | |
Oil interface size | DN50 PN16 | |||||
Cooling water heat exchanger | Double tube heat exchanger | |||||
Cooling water volume | 25 cubic meter/hour 1BAR~4bar max Interface size DN65 PN10 | 28 cubic meter/hour 1BAR~4bar max Interface size DN65 PN10 | 28 cubic meter/hour 1BAR~4bar max DN65 PN10 | |||
Compressor | Emerson Copeland Scroll Flexible Compressor | |||||
Temperature Sensor | PT100 Liquid temperature at inlet and outlet of each group | |||||
Refrigerant | Synthetic heat transfer oil | |||||
Refrigerant | 200L | 200L | 150L | |||
Pipe material | SUS304 | |||||
Low voltage electrical | Schneider/Siemens | |||||
Explosion-proof form | Positive pressure explosion-proof explosion-proof product installation license number: PCEC-2017-B025 | |||||
Size | 3000*2000*2200 | 3000*2000*2200 | 3000*2000*2200 | |||
Weight | 2500KG | 2600KG | 2600KG | |||
Power supply | 380V 50HZ 110KW MAX | 380V 50HZ 125KW MAX | 380V 50HZ 120KW MAX |
Product Description
You may also be interested in these products
LT -45℃~30℃
Industrial/Laboratory Air ChillerCOOLING TEMP -45℃~30℃Configuration DetailsProductDescriptionCooling MethodData Communication InterfaceAPPLICATION SCENARIOProduct Applicationsrecommend products LOW TEMPERATURE COOLING C…
LT 10℃~30℃
Product data downloadConfiguration DetailsProductDescriptionCooling MethodData Communication InterfaceAPPLICATION SCENARIOProduct ApplicationsRecommend products Saving water resources & circulating cooling …
LT -25℃~30℃
Low Temperature Air Cooled ChillerIndustry temperature control solutionLT series fixed frequency chillerASET control4.3 version screen100% safety regulations100% helium detectionTemperature range -80°C-30℃Secondary subcooling technologyConfigurat…