Wuxi Guanya Refrigeration Technology co., ltd
LTS -80℃~80℃

LTS -80℃~80℃



  • Product Description





FEATURE:

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.

Model LTS-802 LTS-803 LTS-804 LTS-806 LTS-808
LTS-802W LTS-803W LTS-804W LTS-806W LTS-808W
Temperature range -80℃~80℃
Temperature control accuracy ±0.1℃  -80℃~-50℃
Flow control 7~25L/min 12~45L/min
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume 4L 5L 6L 8L 10L
Expansion tank volume 10L 10L 15L 15L 20L
System pressure display The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controller Siemens PLC, fuzzy PID control algorithm, with cascade control algorithm
Temperature control Heat transfer medium outlet temperature control mode
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Letter of agreement Ethernet interface TCP/IP protocol
RS485 interface modbus RTU protocol
Internal temperature feedback of equipment Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Closed circulation system The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressor Emerson Copeland/Danfoss Scroll Flexible Compressor
Circulating pump German brand magnetic circulation pump
Evaporator Adopt Danfoss/Gaoli plate heat exchanger
Condenser Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Refrigeration accessories Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Operation panel Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Security With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
In and out interface size G1/2 G1/2 G3/4 G3/4 G3/4




Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
Leave a Message Email Us

we will contact you within 24 hours.

products
Contact US
Tel: + 86 18751545184
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat