LTS -20℃~80℃ Fluoride cooling and heating system
Temperature control during semiconductor manufacturing- Flow control12L/min~45L/min
- Internal circulating liquid4L~10L
- Expansion tank10L~20L
- Place of OriginChina
Product data download
Parameters Detailed
Model | LTS-202 | LTS-203 | LTS-204 | LTS-206 | LTS-208 |
LTS-202W | LTS-203W | LTS-204W | LTS-206W | LTS-208W | |
Temperature range | -20℃~35℃ | ||||
Temperature control accuracy | ±0.1℃ at -20℃~0℃ | ||||
Flow control | 7~25L/min | 12~45L/min | |||
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar. | |||||
Internal circulating fluid volume | 4L | 5L | 6L | 8L | 10L |
Expansion tank volume | 10L | 10L | 15L | 15L | 20L |
System pressure display | The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure) | ||||
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen | |||||
Controller | SPLC, fuzzy PID control algorithm, with cascade control algorithm | ||||
Temperature control | Heat transfer medium outlet temperature control mode | ||||
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control) | |||||
Letter of agreement | Ethernet interface TCP/IP protocol | ||||
RS485 interface modbus RTU protocol | |||||
Internal temperature feedback of equipment | Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment) | ||||
Closed circulation system | The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system | ||||
Compressor | Emerson Copeland/Danfoss Scroll Flexible Compressor | ||||
Circulating pump | Magnetic circulation pump | ||||
Evaporator | Plate heat exchanger | ||||
Condenser | Micro channel condenser (air-cooled) | ||||
Plate heat exchanger (water-cooled), special attention: clean factory water is required | |||||
Refrigeration accessories | Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve) | ||||
Operation panel | LNEYA customized 7-inch color touch screen, temperature curve display\EXCEL data export | ||||
Security | With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions. | ||||
In and out interface size | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 |
Product Description
It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.
1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.
You may also be interested in these products
MD Series Chuck
Quick temperature change control chuckConfiguration DetailsProduct Description -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…
YQH 0℃~-75℃
Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products Suitable for the recovery of various volatile VOCs gases; Fast c…
FLT-100℃~90℃ low temperature cascade
Product data downloadConfiguration Detailschillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products Model FLTZ-803W FLTZ-805W FLTZ-806W FLT-Z808W FLTZ-810W Temp Range -80℃~+90℃ …
FLTZ -45℃~90℃
Product data downloadTemperature control in semiconductor production and testing processesEnsure stable and reliable overall semiconductor process flow from front-end to back-endProductDescriptionchillers that control the processing temperature on…
loading…
已经是到最后一篇内容了!