KRY -25℃~100℃ Vehicle test chiller
Vehicle antifreeze test temperature simulation- Heating Power5.5kW~25kW
- Cooling capacity2.8kW~38kW
- Power range11kW~45kW
- Temperature accuracy±0.5℃
- Flow rate output1~50 L/min
- RefrigerantR404A/R507C
- Weight230KG~830KG
Temperature range is -25℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently while controlling the temperature, and different customized solutions are required for simultaneous control.
The tested object is attached to a test platform adapter.
The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
The test component needs to go through a specific temperature profile and record changes in temperature.
When performing a tolerance test, it usually takes an infinite loop.
Equipped with a powerful circulation pump while ensuring the delivery of highly viscous liquids.
Control the flow output with variable frequency regulation or proportional control valve to achieve high precision control total range 5%~100% adjustment.
Parameters Description
Model | Symbol Unit | KRY-255 | KRY-275 | KRY-2A10 | KRY-2A15 | KRY-2A25 | KRY-2A38W |
KRY-255W | KRY-275W | KRY-2A10W | KRY-2A15W | KRY-2A25W | |||
Temp Range | -25℃~+100℃ | -25℃~+100℃ | -25℃~+100℃ | -25℃~+100℃ | -25℃~+100℃ | -25℃~+100℃ | |
Flow rate output | 1~15 L/min | 1~25 L/min | 1~30 L/min | 1~40 L/min | 1~40 L/min | 5~50 L/min | |
Flow rate accuracy | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | |
Heating power | 5.5KW | 7.5KW | 10KW | 10KW | 15KW | 25KW | |
Cooling capacity | @100℃ | Optional 15KW | Optional 25KW | Optional 38KW | |||
@20℃ | 5.5KW | 7.5KW | 10KW | 15KW | 25KW | 38KW | |
@0℃ | 5.5KW | 7.5KW | 10KW | 15KW | 25KW | 38KW | |
@-20℃ | 5.5KW | 7.5KW | 10KW | 15KW | 25KW | 38KW | |
2.8KW | 3.8KW | 4.6KW | 7KW | 12KW | 16KW | ||
Cooling water | @25℃ | 1500L/H | 2500L/H | 3000L/H | 4000L/H | 6000L/H | 9000L/H |
Power | 380V50HZ | 11KW max | 14KW max | 19KW max | 23KW max | 31KW max | 45KW max |
Dimension | (W) cm | 55*95*175 | 55*95*175 | 55*95*175 | 70*100*175 | 80*120*185 | 100*150*185 |
(A) cm | 55*95*175 | 55*95*175 | 70*100*175 | 80*120*185 | 100*150*185 | / | |
Weight (water cooling) | 230kg | 250kg | 300kg | 320kg | 570kg | 830kg | |
Compression | Emerson Valley Wheel / Danfoss Scroll flexible Compressor | ||||||
Expansion valve | Thermal expansion valve | ||||||
Dry filter | Emerson/Danfoss | ||||||
Evaporator | Plate heat exchanger | ||||||
Input,Display | 7-inch color touch screen \ PLC controller | ||||||
Program edit | 5 procedures may be prepared, each of which may be composed of 40 steps | ||||||
Communication | CAN communication bus | ||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection, etc. | ||||||
Closed circulation system | The whole system is a fully enclosed system. There is no oil mist at high temperature, and low temperature does not absorb moisture in the air. The system does not increase the pressure due to high temperature during operation, and the heat medium is automatically replenished at low temperature. | ||||||
refrigerant | R404A/ R507C | ||||||
Condenser(W) | Tube type heat exchanger (Paris/Shenshi) | ||||||
Condenser(A) | Copper tube aluminum finned heat exchanger (upward wind) | ||||||
Optional | 220V 60HZ Three phase 400V 50HZ Three phase 440V 60HZ Three phase | ||||||
Optional | Extend to -40~+135℃ | ||||||
Optional | Higher precision control of temperature, flow and pressure | ||||||
Optional | Automatic antifreeze filling system |
Product Description
The System Process Flow Is As Follows:
The liquid refrigerant in the evaporator of the unit is exchanged with the circulating air in the interior of the tank. The temperature rises from liquid to gas, and is sucked into the suction port of the compressor. The high-temperature and high-pressure refrigerant gas after compression by the compressor passes through The oil separator separates the refrigerating machine oil carried in the compression process, and then enters the condenser, and exchanges heat with ambient air or cooling water to change from high temperature and high pressure gas to high pressure normal temperature liquid. The high-pressure normal temperature refrigerant liquid is dried by a filter and then throttled and depressurized by an expansion valve, that is, from a high-pressure liquid to a low-pressure liquid. The low-pressure liquid (lower boiling point) enters the evaporator of the unit, and the cooling air is brought to the inside of the tank through the circulating air to achieve refrigeration.
The anti-freeze solution is injected into the 80L pressure vessel, and the fully closed circulation system is adopted. This avoids the opportunity for the antifreeze to contact with the outside air and ensures the condensation of the water. After the expansion tank is protected by nitrogen, the temperature range of the heat transfer liquid is also broadened because its boiling point is increased. In addition, oxidation of the thermally conductive liquid in contact with oxygen in the environment is also avoided, thereby extending the useful life of the thermally conductive liquid.
You may also be interested in these products
KRY -40℃~+100℃ (1to6)
Product data downloadtemperature control, flow controlParameters DetailedProductDescriptionrecommend products The components are cooled and heated internally through ethylene glycol aqueous solution for testing -40 ° …
KRY -40℃~+100℃ (1to1)
Temperature control in the testing process of new energy vehicle componentsParameters DetailedEquipment appearanceGeneral equipmentMultichannel equipmentMulti channel independent temperature controlVariable frequency regulationClient AClient BAppl…
KRY -40℃~+100℃ (1to2)
Product data downloadParameters DetailedProductDescriptionYou may also be interested in these products Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature contro…
KRY -40℃~+100℃ (1to3)
Product data downloadKRY -40℃~100℃ 1&3S (3 sets of auxiliary temperature control, Pressure/Flow controlled separately)ProductDescriptionYou may also be interested in these products Dimension(A) cm Temperature r…