Cooling Heating Circulator
HR-25℃~200℃- Heating Power2.5kW~15kW
- Cooling capacity1kW~15kW
- Power range4kW~21kW
- Medium accuracy±0.5℃
- RefrigerantR404A/R507C
- Weight150KG~320KG
Parameters Detail
Model | HR-25N | HR-35N | HR-50N | HR-70N | HR-100N | HR-150N | |
Temperature Range | -25℃~200℃ | ||||||
Controller | PID adaptive controller | ||||||
Temperature Control | heat-conducting medium outlet temp.control | ||||||
Temperature Feedback | Heat-conducting medium temperature feedback PT100(measure inlet temperature and outlet temperature) | ||||||
Temp. Accuracy | ±0.5℃ | ||||||
Heating Power | 2.5kW | 3.5kW | 5.5kW | 7kW | 10kW | 15kW | |
Cooling Capacity | 200℃ | 2.5kW | 3.5kW | 5.5kW | 7kW | 10kW | 15kW |
100℃ | 2.5kW | 3.5kW | 5.5kW | 7kW | 10kW | 15kW | |
20℃ | 2.5kW | 3.5kW | 5.5kW | 7kW | 10kW | 15kW | |
-5℃ | 2kW | 3kW | 4.5kW | 6.6kW | 8kW | 12kW | |
-20℃ | 1kW | 1.8kW | 2.8kW | 3.8kW | 4.6kW | 7kW | |
Circulation Pump Flow | Max20L/min | Max35L/min | Max35L/min | Max50L/min | Max60L/min | Max110L/min | |
Circulation Pump Pressure | 1.2BAR | 1.2BAR | 1.2BAR | 1.2BAR | 1.5BAR | 1.5BAR | |
Tank Volume | 8L | 13L | 15L | 18L | 22L | 30 | |
Be equipped with extra connection of expansion tank(ZG1/2) | |||||||
Compressor | Mitsubishi | Copeland | Copeland | Copeland | Copeland | Copeland | |
Evaporator | Plate heat exchanger | ||||||
Operation Panel | Display setting temperature and outlet and inlet temperature, 7-inch color touch screen | ||||||
Data Record | U disk data export, Excel form, error record | ||||||
Temperature Record | Record setting temperature, outlet and inlet temperature | ||||||
Safety Protection | Self-diagnosis function; freezer overload protection; high pressure switch; overload relay; thermal protection device and other safety protection. | ||||||
Closed Circulation System | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | ||||||
Refrigerant | R-404A/R507C | ||||||
Connection Size | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | |
Dimension(cm) | air-cooled | 40*70*130 | 45*70*160 | 45*70*160 | 55*70*175 | 65*85*185 | 70*85*185 |
Weight | air-cooled | 150kg | 165kg | 235kg | 265kg | 290kg | 320kg |
Power | AC 220V 50HZ | AC 380V 50HZ | AC 380V 50HZ | AC 380V 50HZ | AC 380V 50HZ | AC 380V 50HZ | |
4kW | 5.6kW (max) | 8kW (max) | 11kW (max) | 15.5kW (max) | 22kW (max) | ||
Case Material | Cold rolled steel | ||||||
Optional | MODBUS RTU Protocl, RS 232 interface | ||||||
Optional Power | 220V 60HZ three-phase,440V~480V 60HZ three phase |
Product Description
HRT Knowledge
The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it’s blocked, then the temperature will go up. A main cause of the air compressor failure at high temperature is the blockage of the cooler.
So what are the causes of the blockage of the cooler?
Dust is the most common cause of air compressor cooler blockage. It usually happens when there is no dust cleaning for air compressor cooler for a long time. On the other hand is the dusty environment around the air compressor.
If the place of air compressor station is harsh, and it is not well protected, blockage also occurs. For example, things as the broken thread of textile industry, sawdust of furniture factory, iron filings of steel works float in the air and stick to the cooler will lead to blockage.
Some users bought bad-quality air compressor lubricants out of their bargin-loving heart. Or if the air compressor runs in a high temperature for a long time, the inside of the cooler will form carbon and cause blockage. Reducing the amount of lubricating oil flowing through the radiator, results in poor heat dissipation.
There are three main reasons for the blockage of air compressor cooler, and we’d like to inform you to prevent the clogging of the cooler, ensure the normal operation of the cooler and improve the production efficiency. At the same time, it also requires users to clean the coolers daily, do the maintenance work in time, and find professional after-sales staff to deal with the problem.
recommend products
SUNDI Z Frequency conversion series
HIGHLY TEMPERATURE CONTROL SYSTEMSAir-cooling & Water-coolingDETAIL ADVANTAGE,STRIVING FOR EXCELLENCEConfiguration DetailsFLUID CIRCULATION CLOSED TEMPERATURE CONTROLWIDE RANGE OF APPLICATION INDUSTRY SERVICESAPPEARANCE DETAILS OUALITY CONTROL…
SUNDI -10℃~150℃
Product data downloadMaterial temperature and equipment outlet temperature control optionalDynamic Cooling Heating SystemControl temperatureTemperature AccuracyConfiguration DetailsWorking PrincipleYou may also be interested in these products …
SUNDI -80℃~250℃
Product data downloadProductDescriptionConfiguration DetailsWorking PrincipleYou may also be interested in these products ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature…
SUNDI-320/420W/430W
Product data downloadMaterial temperature and equipment outlet temperature control optionalDynamic Cooling Heating SystemControl temperatureTemperature AccuracyConfiguration DetailsProductDescriptionprincipleApplicationsFor pilot production/experi…
loading…
已经是到最后一篇内容了!