Search the whole station

UC series
UC series
UC series

Heating Circulator

UC +50℃~300℃
  • Heating Power3.5kW~130kW
  • Cooling power1kW~130kW
  • Power range5kW~136kW
  • Temperture accuracy±0.5℃

Thermal oil heating System

Temp. Control 50~300℃, Accuracy of ±0.5°C

Note: The UC series can only control the temperature of the thermal conductivity medium, while the UST series can not only control the temperature of the thermal conductivity medium but also reflect the temperature of the material.

Configuration Details

Model UC-3530 UC-5530 UC-7530 UC-A1030 UC-A1530 UC-A2530 UC-A3830 UC-A6030 UC-A9530 UC-A13030
Temperature range 50℃~300℃
Controller PID adaptive controller
Temp. control optional Heat-conducting medium outlet temp. control
 Communication protocol MODBUS RTU protocol  RS 485 interface
Temperature feedback Heat-conducting medium temperature feedback PT100
Temp. accuracy ±0.5℃
Heating power 3.5kW 5.5kW 7.5kW 10kW 15kW 25kW 38kW 60kW 95kW 130kW
Cooling capacity 300℃ 3.5kW 5.5kW 7.5kW 10kW 15kW 25kW 38kW 60kW 95kW 130kW
  200℃ 3.5kW 5..5kW 7.5kW 10kW 13kW 25kW 38kW 60kW 95kW 130kW
  100℃ 2.8kW 4kW 5kW 7kW 12kW 20kW 30kW 48kW 76kW 100kW
  65℃ 1kW 1.8kW 2.2kW 3kW 5kW 8.5kW 12kW 19kW 30kW 40kW
Circulation pump Max35L/min 1.2BAR Max35L/min 1.2BAR Max50L/min 1.2BAR Max50L/min 1.2BAR Max110L/min 1.5BAR Max150L/min 1.5BAR Max200L/min 1.5BAR Max250L/min 2.5BAR Max400L/min 2.5BAR Max400L/min 2.5BAR
Heater Flanged pipe electric heater
Independent temperature limiter Lneya
Cooler Plate heat exchanger/Tube heat exchanger
Operation panel Display set temperature and measured temperature,key operation input temperature
Sefety protection Self-diagnostics;High pressure switch,overload relay、variety of security features such as thermal protection devices.
Closed circulation system The entire system is a fully enclosed system,no oil mist at high temperatures、low temperature does not absorb moisture in the air
System The system does not increase the pressure due to high temperature during operation,low temperature automatically replenishes the heat transfer medium.
Connection size ZG3/4 ZG3/4 ZG1 ZG1 ZG1 DN32 PN10 DN40 PN10 DN40 PN10 DN50 PN10 DN50 PN10
Dimensions cm 40*70*130 40*70*130 45*70*160 45*70*160 70*100*175 70*100*175 80*100*185 150*100*185 200*145*205 200*145*205
Weight kg 95 110 120 160 195 265 395 615 1220 1400
Power 5KW 7KW 9KW 12kw 17kw 28kw 41kw 65kw 101kw 136kw
Case material Cold rolled sheet spray
Optional Optional 7-inch color touch screen,recording temperature curve,data export using excel format
Optional SUS304 shell
Optional Optional external touch screen controller,communication line distance 10m
Optional Optional explosion-proof touch screen control system(ExdeIIBT4),communication line distance 10m
Optional power 220V 60HZ three phase,440V~480V 60HZ three phase

Product Description

  • Heating Circulator UC series with function from high temperature to cooling process, from 300℃~50℃.
  • Equipped with heating cooling container, with large heat transfer area, fast heat-up and cool-down, small heat transfer oil demand.
  • Can heat-up and cool-down continuously.
  • The whole cycle is full closed,there is no oil mist at high temperature, heat transfer oil can not be oxidized and browning.
  • With function of internal PT100 for correcting internal circulation.
  • The whole system is closed with expansion tank, the expansion tank and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in expansion tank is limited to 60℃.

Send us a message about Heating Circulator
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

recommend products

loading…

已经是到最后一篇内容了!

Expand more!