AES -115℃~225℃

  • Time switching10s~20s
  • RefrigerantR404A/R23/R14/R508B
  • Cooling water0.6m³/h~3m³/h
  • Power range3.7kW~7.5kW

Product data download

Parameters Detailed

Model AES-4535 AES-6035 AES-8035 AES-A1035W AES-A1235W
AES-4535W AES-6035W AES-8035W
Temp. Range -45℃~225℃ -60℃~225℃ -80℃~225℃ -100℃~225℃ -120℃~225℃
Heating Power 3.5kW 3.5kW 3.5kW 4.5kW 4.5kW
Temp. Control Accuracy ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃
Temp. Conversion Time -25℃ to 150℃ Approximately 10S
150℃ to  -25℃
Approximately 20s
-45℃ to 150℃ Approximately 10S
150℃to  -45℃
Approximately 20s
-55℃ to 150℃ Approximately 10S
150℃to  -55℃
Approximately 15s
-70℃ to 150℃ Approximately 10S
150 ℃to  -70℃
Approximately 20s
-80℃ to 150℃ Approximately 11S
150℃to  -80℃
Approximately 20s
Air Requirement Air Cleaner<5um
Air Oil Content:<0.1ppm
Air Temp&Humidity:5℃~32℃  0~50%RH
Air Handing Capacity 7m3/h ~ 25m3/h  Pressure 5bar~7.6bar
System Pressure Dispiay Pressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure);
Pressure of circulatory system is detected by pressure sensor and displayed on touch screen.
Controller Siemens PLC, Fuzzy PID Control algorithm.
Temp. Control Control of outlet temperature
Programmable 10 procedures can be developed, and each program can be composed of 45 steps
Communicating Protocol Ethernet Interface TCP/IP Protocol.
Internal Temp. Feedback Equipment outlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured) .
Temp. Feedback T Temperature Sensor
Compression Engine Taikang,France Taikang,France Taikang,France Italy Duling Italy Duling
Evaporimeter Double-pipe (heat) Exchanger
Calorifier Flanged Barrel Heater
Refrigeration Accessory Danfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves, solenoid valves).
Operation Panel LNEYA custom 7-inch color touch screen, temperature curve display\ EXCEL data export.
Safe Guarding With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
Cryogen Topsubmixed Refrigerant
External Insulation Hose 8m DN32 fast coupling clamp for easy outgoing insulation hose
Refrigerant R404A R404A/R23 R404A/R508B R404A/R23/R14 R404A/R23/R14
Shape Dimension (Wind)cm 54*69*132 54*69*132 75*73*133 80*120*185 100*150*185
Shape Size (Water)cm 54*69*132 54*69*132 75*73*133 70*100*175 80*120*185
Air-Cooled Type Copper tube aluminum fin condensation mode, upper and out type, condensing fan using Germany EBM axial flow fan.
Water-Cooled Type W Type W is water cooled
Water-Cooled Condenser Sleeve type heat exchanger (Paris/ Shen’s)
Cooling Water Quantity At 25℃ 0.6m3/h 1.2m3/h 1.6m3/h 2.6m3/h 3m3/h
Source 380V 50HZ 3.7kW max 5kW max 5kW max 6.8kW max 7.5kW max
Source Customizable 460V 60HZN 220V 60HZ three-phase
Shell Material Cold rolled sheet spray (Standard Colour 7035).
Temp. Spread High Temperature To +300℃

Product Description

Provides accurate and fast ambient temperature (-120 °C ~ +300 °C) for chips, modules, integrated circuit boards, and electronic components. It is an indispensable instrument for product electrical performance testing, failure analysis, and reliability assessment.

Widely used in semiconductor companies, aerospace, optical communications, universities, research institutes and other fields.

Compared to the traditional thermostat, there are several features:
Temperature range: -120 °C ~ +300 °C;
The temperature rise and fall is very fast, -55 °C ~ 150 °C < 10 seconds;
Temperature control accuracy: ±1 °C;
Temperature setting capability: ±0.1 °C;
Temperature display capability: ±0.1 °C;
Maximum air flow: 25m3/h;
Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time;