HEATING CIRCULATOR (WATER COOLING TYPE)

UST 10℃~300℃
  • Heating Power5.5kW~95kW
  • Cooling power1.8kW~95kW
  • Power range7kW~96kW
  • Temperture accuracy±0.5℃

Parameters Detailed

Model UST-5530 UST-5530W UST-7530 UST-7530W UST-A1030 UST-A1030W UST-A1530 UST-A1530W UST-A2530 UST-A2530W UST-A3830  UST-A3830W UST-A6030 UST-A6030W UST-A9530  UST-A9530W
Medium temperature range RT+10℃~+300℃
Control system Feedforward PID, model-free self-building tree algorithm, PLC controller
Temperature control mode selection Material temperature control and equipment outlet temperature control mode can be freely selected
Temperature difference control The temperature difference between the equipment outlet temperature and the reaction material temperature can be controlled and set
Program editing 20 programs can be compiled, and each program can compile 40 steps
MODBUS RTU protocol RS 485 interface, Ethernet interface
Communication protocol MODBUS RTU 协议  RS 485接口,以太网接口
External temperature feedback PT100 or 4~20mA or communication setting (default PT100)
Temperature feedback Equipment heat transfer medium inlet temperature, outlet temperature, reactor material temperature (external temperature sensor) three-point temperature
Thermal medium temperature control accuracy ±0.5℃ ±1℃
Reaction material temperature control accuracy ±1℃
Heating Power kW 5.5 7.5 10 15 25 38 60 95
Cooling capacity kW  AT 300 ℃ 5.5 7.5 10 15 25 38 60 95
200 ℃ 5.5 7.5 10 15 25 38 60 95
100 ℃ 4 5 7 12 20 30 48 76
65 ℃ 1.8 2.2 3 5 8.5 12 19 30
Flow pressure max
L/min bar
35 50 50 110 150 200 250 400
2 2 2 2.5 2.5 2.5 2.5 2.5
Operation panel 7-inch color touch screen, temperature curve display and recording
Safety protection With self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device and other safety protection functions.
Closed circulation system The whole system is a fully enclosed system. There will be no oil mist at high temperature and no moisture in the air at low temperature. The system will not increase pressure due to high temperature during operation, and the heat transfer medium will be automatically replenished at low temperature.
Interface size ZG3/4 ZG3/4 ZG3/4 ZG1 DN32 PN10 DN40 PN10 DN40 PN10 DN50 PN10
Cooling water interface ZG3/4 ZG3/4 ZG3/4 ZG1 DN32 PN10 DN40 PN10 DN40 PN10 DN50 PN10
Dimensions cm 40*70*130 45*70*160 40*70*160 70*100*175 70*100*175 80*120*185 150*100*185 200*145*205
Weight kg 110 120 160 195 265 395 615 950
Power supply 380V max 7kW 9kW 12kW 17kW 28kW 41kW 65kW 96kW
Casing material Cold-rolled plate spraying (standard color 7035)
Optional Optional Ethernet interface, equipped with computer operating software
Optional Optional external touch screen controller, communication line distance 10M
Optional power supply 100V 50HZ single phase, 110V 60HZ single phase, 230V 60HZ single phase, 220V 60HZ three-phase, 440V~460V 60HZ three-phase