HEATING CIRCULATOR (WATER COOLING TYPE)
UST 10℃~300℃- Heating Power5.5kW~95kW
- Cooling power1.8kW~95kW
- Power range7kW~96kW
- Temperture accuracy±0.5℃
It is suitable for the needs of various process production and experimental use in pharmaceutical and chemical enterprises. It can realize high temperature cooling process, directly cooling from high temperature of 300 degrees to 50 degrees. Equipped with a heating and cooling integrated container, the heat exchange area is large, the heating and cooling rate is fast, and the demand for heat transfer oil is small. The entire cycle of the product is closed, there is no oil mist volatilization at high temperature, and the heat transfer oil will not be oxidized and browned; it has the function of correcting the internal cycle temperature probe PT100, and has self-diagnosis and intelligent safety alarm. The equipment is equipped with a variety of safety protection functions such as high-voltage pressure switches, overload relays, and thermal protection devices to ensure the safety of your experiments and production.
Parameters Detailed
Model | UST-5530 UST-5530W | UST-7530 UST-7530W | UST-A1030 UST-A1030W | UST-A1530 UST-A1530W | UST-A2530 UST-A2530W | UST-A3830 UST-A3830W | UST-A6030 UST-A6030W | UST-A9530 UST-A9530W | |
Medium temperature range | RT+10℃~+300℃ | ||||||||
Control system | Feedforward PID, model-free self-building tree algorithm, PLC controller | ||||||||
Temperature control mode selection | Material temperature control and equipment outlet temperature control mode can be freely selected | ||||||||
Temperature difference control | The temperature difference between the equipment outlet temperature and the reaction material temperature can be controlled and set | ||||||||
Program editing | 20 programs can be compiled, and each program can compile 40 steps MODBUS RTU protocol RS 485 interface, Ethernet interface |
||||||||
Communication protocol | MODBUS RTU 协议 RS 485接口,以太网接口 | ||||||||
External temperature feedback | PT100 or 4~20mA or communication setting (default PT100) | ||||||||
Temperature feedback | Equipment heat transfer medium inlet temperature, outlet temperature, reactor material temperature (external temperature sensor) three-point temperature | ||||||||
Thermal medium temperature control accuracy | ±0.5℃ | ±1℃ | |||||||
Reaction material temperature control accuracy | ±1℃ | ||||||||
Heating Power kW | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
Cooling capacity kW AT | 300 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 |
200 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
100 ℃ | 4 | 5 | 7 | 12 | 20 | 30 | 48 | 76 | |
65 ℃ | 1.8 | 2.2 | 3 | 5 | 8.5 | 12 | 19 | 30 | |
Flow pressure max L/min bar |
35 | 50 | 50 | 110 | 150 | 200 | 250 | 400 | |
2 | 2 | 2 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Operation panel | 7-inch color touch screen, temperature curve display and recording | ||||||||
Safety protection | With self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device and other safety protection functions. | ||||||||
Closed circulation system | The whole system is a fully enclosed system. There will be no oil mist at high temperature and no moisture in the air at low temperature. The system will not increase pressure due to high temperature during operation, and the heat transfer medium will be automatically replenished at low temperature. | ||||||||
Interface size | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Cooling water interface | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Dimensions cm | 40*70*130 | 45*70*160 | 40*70*160 | 70*100*175 | 70*100*175 | 80*120*185 | 150*100*185 | 200*145*205 | |
Weight kg | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 950 | |
Power supply 380V max | 7kW | 9kW | 12kW | 17kW | 28kW | 41kW | 65kW | 96kW | |
Casing material | Cold-rolled plate spraying (standard color 7035) | ||||||||
Optional | Optional Ethernet interface, equipped with computer operating software | ||||||||
Optional | Optional external touch screen controller, communication line distance 10M | ||||||||
Optional power supply | 100V 50HZ single phase, 110V 60HZ single phase, 230V 60HZ single phase, 220V 60HZ three-phase, 440V~460V 60HZ three-phase |
You may also be interested in these products
SUNDI Z Frequency conversion series
HIGHLY TEMPERATURE CONTROL SYSTEMSAir-cooling & Water-coolingDETAIL ADVANTAGE,STRIVING FOR EXCELLENCEConfiguration DetailsFLUID CIRCULATION CLOSED TEMPERATURE CONTROLWIDE RANGE OF APPLICATION INDUSTRY SERVICESAPPEARANCE DETAILS OUALITY CONTROL…
SUNDI -10℃~150℃
Material temperature and equipment outlet temperature control optionalDynamic Cooling Heating SystemControl temperatureTemperature AccuracyConfiguration DetailsYou may also be interested in these products Fully enclosed …
SUNDI -80℃~250℃
Product data downloadProductDescriptionConfiguration DetailsWorking PrincipleYou may also be interested in these products ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature…
SUNDI-320/420W/430W
Product data downloadMaterial temperature and equipment outlet temperature control optionalDynamic Cooling Heating SystemControl temperatureTemperature AccuracyConfiguration DetailsProductDescriptionprincipleApplicationsFor pilot production/experi…
loading…
已经是到最后一篇内容了!