Maintenance of chiller for water cooling unit of UV etching machine
Ultraviolet etching machine water cooling unit chiller is a kind of refrigeration equipment widely used in industrial production. It can provide an effective cooling environment for different industrial productions, and it can provide great convenience for many industrial productions.
1. The use of the water cooling unit chiller of many UV etching machines requires a better understanding of basic knowledge such as product performance. For example, after the on-site installation of the chiller products equipped with UV etching machines, if no accidents are found in the appearance inspection If it is damaged, you can directly open the relevant valves (you should read the manufacturer's instruction manual first. During transportation, the valves on the unit are generally closed) and start-up debugging. If it is found that the refrigerant has been leaked or insufficient, first find out the leak point and eliminate the leakage phenomenon, and then add the specified brand of refrigerant according to the requirements of the product instruction manual, and pay attention to the refrigerant charge should meet the technical requirements.
2. When using the chiller of the water cooling unit of the UV etching machine, special attention should be paid to the refrigerant of the chiller of the water cooling unit of the UV etching machine. In general, it is required to charge the refrigerant of the chiller equipped with the UV etching machine and the The refrigerant brand is in accordance with the regulations, and the refrigerant charge is insufficient, which will lead to insufficient cooling capacity.
3. In the selection of chiller for the water cooling unit of the UV etching machine, there are many operating temperatures that are not fixed, and the operation methods are also different. The temperature from the water outlet to the water inlet is different.
4. Users generally pay great attention to the maintenance of the chiller of the water cooling unit of the UV etching machine. Generally, they will regulate the start-up time, because it cannot be opened for a long time without interruption, which will cause great damage to the internal parts, and then affect the normal operation of the machine.
5. When operating the chiller of the water cooling unit of the UV etching machine, it is necessary to pay attention to the change of the internal temperature and keep it within the set range. Once the allowed temperature is exceeded, it is an abnormal situation. Exhaust faults.
6. After the water cooling unit chiller of the UV etching machine has been used for a period of time, its oil tank needs to be cleaned regularly, because moisture will be generated at the bottom of it, which will damage the cooling coil.
7. The oil in the chiller of the water cooling unit of the UV etching machine should also be kept clean, and its filter should also be cleaned and inspected regularly to prevent debris and dirt from remaining.
February 6, 2021If you need equipment to distill CBD, you need to scrutinize your choices, as the equipment can vary in its features and design. When you use equipment that produces a CBD distillate, you want to seek out a system made by a manufacturer that provides proven and reliable products. You should also work with a business that can train you on the use of the equipment you buy.view
December 5, 2022On November 18, 2022, it was sponsored by the Jiangsu Provincial Association for Science and Technology, the Provincial Taiwan Affairs Office, the Provincial Department of Industry and Information Tec...view
January 13, 2023Recently, the Jiangsu Provincial Productivity Promotion Center officially released the evaluation results of the unicorn enterprises and gazelle enterprises in 2022 in Jiangsu and the high-tech zone, ...view
January 11, 2018Industrial Chiller:Industrial Chiller varies from dynamic temp. Special Chiller:Special Chiller consist of Multi-reactor chiller (TCU).Environmental Chamber:The test object is connected to a testing adapter. Industrial Freezer:Industrial freezer consist oview
July 4, 2018What are the characteristics and functions of ultra low freezer: 1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the proce...view
January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃)
Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view