Precautions for using the wafer testing temperature control system
The wafer testing temperature control system can provide high and low temperature environments for experimental use. However, as an instrument, its operation also needs to follow certain precautions. This article will introduce in detail the operating precautions of the wafer testing temperature control system to ensure the accuracy and safety of the experiment.
The wafer testing temperature control system mainly consists of a refrigeration system, a heating system, a control system and a temperature sensor. It can achieve accurate control of high and low temperature environments by adjusting the parameters of the heating system and refrigeration system.
FLT-100℃~90℃
Single channel air-cooled cooler, mainly designed for etching machines. It is used to provide independent temperature control for the chamber sid…
FLTZ -45℃~90℃
Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates continuously for 24 hours The semiconductor temperature control device Chiller is mainly used for p…
loading…
已经是到最后一篇内容了!
Before using the wafer to test the temperature control system, we need to conduct a series of checks. Check whether the power connection of the device is normal and whether the power plug is tight. Secondly, check whether the pipeline connections of the equipment are tight and whether there are leaks. In addition, the internal cleanliness of the equipment should be checked to ensure the accuracy of the experimental results.
When operating the wafer testing temperature control system, we need to pay attention to the following tips. Avoid moving or tilting the equipment while it is in operation to avoid unnecessary injury. Secondly, make sure that the experimental samples are placed securely and do not place them on the edge or sliding parts of the equipment to avoid falling and damaging the equipment or causing personal injury.
When setting the temperature, adjust the temperature step by step and always pay attention to the difference between the device’s display temperature and the set temperature. If the difference is too large, the parameters of the heating system and refrigeration system should be adjusted in time. At the same time, it is necessary to keep the equipment clean and clean the condenser, evaporator and other components regularly to ensure the heat dissipation and cooling effect of the equipment.
Long-term use of the wafer test temperature control system may result in equipment performance degradation or failure. Therefore, we must regularly inspect and maintain the equipment to detect and solve problems in a timely manner. At the same time, the filter, oil and other accessories of the equipment should be replaced regularly according to the equipment instructions to ensure the normal operation of the equipment.
In short, the operation of the wafer testing temperature control system requires attention to many aspects. During use, we must strictly abide by the operating procedures of the equipment and always pay attention to the operating status of the equipment and changes in experimental results. At the same time, you also need to pay attention to tips and equipment maintenance precautions to ensure the accuracy and safety of the experiment.
Provide 7 * 24 free consultation and comprehensive solutions


Email: sales@cnzlj.com
WhatsApp: 086 13912479193
Related recommendations
-
How to purchase a power management chip temperature test system?
366The power management chip temperature test system is an important equipment used to test the performance and reliability of semiconductor chips in different temperature environments. When purchasing this type of test equipment, you need to...
View details -
LTS -60℃~80℃
594It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer med...
View details -
FLTZ Variable Frequency Series Multi-channel Chillers
345APPLICATIONS Semiconductor air cooling & water cooling Chiller is mainly used for precise temperature control in semiconductor production and testing. Products include fluid fluorinated liquid temperature control (minimum -100 degre...
View details -
FLT -45℃~40℃
1015Model FLT-402 FLT-402W FLT-403 FLT-403W FLT-404 FLT-404W FLT-406 FLT-406W FLT-408 FLT-408W FLT-410 FLT-410W FLT-415 FLT-415W Temp Control -45℃~40℃ Temp control accuracy ±0.1℃ Flow Control 10~25L/min 5bar max 15~45L/m...
View details
Submit for consultation
We will reply to you within 24 hours