Ricerca nell'intera stazione

LTS -20℃~80℃

LTS -20℃~80℃ Fluoride cooling and heating system

Temperature control during semiconductor manufacturing
  • Controllo del flusso12L/min~45L/min
  • Internal circulating liquid4L~10L
  • Serbatoio di espansione10L~20L
  • Luogo di origineCina

Download dei dati del prodotto

Parametri dettagliati

ModelloLTS-202LTS-203LTS-204LTS-206LTS-208
LTS-202WLTS-203WLTS-204WLTS-206WLTS-208W
Intervallo di temperatura -20℃~35℃
Precisione del controllo della temperatura±0.1℃  at  -20℃~0℃
Controllo del flusso 7~25L/min12~45L/min
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume4L5L6L8L10L
Volume del vaso di espansione10L10L15L15L20L
Visualizzazione della pressione del sistemaThe pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
ControllorePLC, algoritmo di controllo PID fuzzy, con algoritmo di controllo a cascata
Temperature controlModalità di controllo della temperatura di uscita del fluido di trasferimento del calore
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Lettera di accordoInterfaccia Ethernet Protocollo TCP/IP
Interfaccia RS485 protocollo modbus RTU
Internal temperature feedback of equipmentEquipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Sistema di circolazione chiusoThe whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
CompressoreEmerson Copeland/Danfoss Scroll Flexible Compressor
Pompa di circolazioneMagnetic circulation pump
EvaporatoreScambiatore di calore a piastre
CondensatoreMicro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Accessori per la refrigerazioneDanfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Pannello operativoSchermo tattile a colori da 7 pollici personalizzato LNEYA, visualizzazione della curva di temperatura
SicurezzaWith self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
Dimensioni dell'interfaccia di ingresso e di uscitaZG1/2ZG1/2ZG3/4ZG3/4ZG3/4

Descrizione del prodotto

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
Ottimizzare il campionamento della temperatura e la velocità di risposta, algoritmo di controllo appositamente progettato, in grado di rispondere rapidamente al controllo della temperatura stabile.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Fare clic sul messaggio online per richiedere i dettagli del prodotto
Send us a message about LTS series
Send us a message about LTS series
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

  • Air Cooling Chiller AET SERIES"      /&gt;<figcaption><span>Parameters DetailedProductDescriptionREQUEST A QUOTERecommended products           Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc….</span></figcaption></figure></a></div><div class= Air Cooling Chiller AET SERIES

    Parameters DetailedProductDescriptionREQUEST A QUOTERecommended products Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc….

  • MD -75℃~225℃"      /&gt;<figcaption><span>Quick temperature change control chuckConfiguration DetailsProduct Description           -75℃ to 225°C          Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…</span></figcaption></figure></a></div><div class= MD -75℃~225℃

    Quick temperature change control chuckConfiguration DetailsProduct Description -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…

  • YQH 0℃~-75℃"      /&gt;<figcaption><span>Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products        Suitable for the recovery of various volatile VOCs gases; Fast c…</span></figcaption></figure></a></div><div class= YQH 0℃~-75℃

    Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products Suitable for the recovery of various volatile VOCs gases; Fast c…

  • FLT-100℃~90℃ low temperature cascade"      /&gt;<figcaption><span>Product data downloadConfiguration Detailschillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products                 Model FLTZ-803W FLTZ-805W FLTZ-806W FLT-Z808W FLTZ-810W Temp Range -80℃~+90℃ …</span></figcaption></figure></a></div><div class= FLT-100℃~90℃ low temperature cascade

    Product data downloadConfiguration Detailschillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products Model FLTZ-803W FLTZ-805W FLTZ-806W FLT-Z808W FLTZ-810W Temp Range -80℃~+90℃ …

caricamento...

已经是到最后一篇内容了!

Espandere di più!