Ricerca nell'intera stazione

Refrigeratore a gas LQ -40°C~-110°C

LQ -40°C~-110°C

Semiconductor test chiller For non corrosive gas cooling
  • Potenza di riscaldamento2,5kW~25kW
  • Capacità di raffreddamento0,25kW~25kW
  • Gamma di potenza6,5kW~50kW
  • Accuratezza media±0.3℃
  • Pressione di flusso20L/min~150L/min 2,5bar
  • RefrigeranteR404A/R508B

Download dei dati del prodotto

Parametri dettagliati

Modello LQ-4015 LQ-4030 LQ-4060 LQ-40100 LQ-7515 LQ-7530 LQ-7560 LQ-75100
LQ-4015W LQ-4030W LQ-4060W LQ-40100W LQ-7515W LQ-7530W LQ-7560W LQ-75100W
Flusso di gas 15m3/h 30m3/h 60m3/h 100m3/h 15m3/h 30m3/h 60m3/h 100m3/h
lowest temp. -40℃ -40℃ -40℃ -40℃ -75℃ -75℃ -75℃ -75℃
Area di scambio termico 0.8m2 1.5m2 3m2 5m2 1.5m2 2.5m2 5m2 9m2
Materiale dello scambiatore di calore Standard configuration sus304 contains a small amount of copper
Gas inlet and outlet diameter G3/8 G1/2 G1 DN50 G3/8 G1/2 G1 DN50
Sistema di controllo Programmable controller and module
Visualizzazione e registrazione 7-inch color touch screen, record curve temperature and alarm conditions
compressor France Taikang/Emerson Copeland
Alimentazione 220V 50HZ 220V 50HZ 380V 50HZ 380V 50HZ 220V 50HZ 220V 50HZ 380V 50HZ 380V 50HZ
1,2KW 1,8KW 3,5KW 7KW 2KW 3KW 6KW 11.5KW

Descrizione del prodotto



It is used to cool the gas (non corrosive) or recover it as non corrosive gas by condensation and liquefaction.

Pressure resistance of gas heat exchange system: 25bar; The temperature range is – 40 ℃ ~ – 75 ℃, which can meet different temperatures;

The secondary subcooling technology is adopted, with rapid refrigeration and low refrigeration temperature;

Semi closed piston compressor, scroll flexible compressor and fully closed piston compressor of imported brands are adopted;

The evaporator adopts casing heat exchanger, which has the advantages of small volume, long residence time and high efficiency;

Danfoss expansion valve and Emerson electronic expansion valve are adopted, with high temperature control accuracy;

Siemens plcs7-200 / 300 and lneya touch screen display are used for automatic control operation;

The whole machine is installed. The system has been tested in the factory. Users only need to install the refrigerant pipeline and cooling water pipeline to run;

Factory test: each refrigeration unit shall be tested with load in the factory for no less than 12 hours;


Fare clic sul messaggio online per richiedere i dettagli del prodotto
Send us a message about LQ series
Send us a message about LQ series
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

  • Air Cooling Chiller AET SERIES"      /&gt;<figcaption><span>Parameters DetailedProductDescriptionREQUEST A QUOTERecommended products           Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc….</span></figcaption></figure></a></div><div class= Air Cooling Chiller AET SERIES

    Parameters DetailedProductDescriptionREQUEST A QUOTERecommended products Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc….

  • MD -75℃~225℃"      /&gt;<figcaption><span>Quick temperature change control chuckConfiguration DetailsProduct Description           -75℃ to 225°C          Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…</span></figcaption></figure></a></div><div class= MD -75℃~225℃

    Quick temperature change control chuckConfiguration DetailsProduct Description -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…

  • YQH 0℃~-75℃"      /&gt;<figcaption><span>Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products        Suitable for the recovery of various volatile VOCs gases; Fast c…</span></figcaption></figure></a></div><div class= YQH 0℃~-75℃

    Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products Suitable for the recovery of various volatile VOCs gases; Fast c…

  • FLT-100℃~90℃ low temperature cascade"      /&gt;<figcaption><span>Product data downloadConfiguration Detailschillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products                 Model FLTZ-803W FLTZ-805W FLTZ-806W FLT-Z808W FLTZ-810W Temp Range -80℃~+90℃ …</span></figcaption></figure></a></div><div class= FLT-100℃~90℃ low temperature cascade

    Product data downloadConfiguration Detailschillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products Model FLTZ-803W FLTZ-805W FLTZ-806W FLT-Z808W FLTZ-810W Temp Range -80℃~+90℃ …

caricamento...

已经是到最后一篇内容了!

Espandere di più!