Ricerca nell'intera stazione

SUNDI -10℃~150℃

KRY direct cooling heating system

Control Temperature and Flow
  • Capacità di raffreddamento0.5kW~10kW
  • Heating capacity0.5kW~10kW
  • RefrigeranteR134A/R1234yf
  • Peso115KG~300KG

Dettagli sulla configurazione

Modello GD-500-C-WS
Inner box size
(W*H*D)cm
90*65*90
Intervallo di temperatura -70~+150℃ 
Heating rate (No load) (+20~150℃) 2℃/min (5~25℃ customizable)
Velocità di raffreddamento (No load) (+20~-70℃) 1℃/min (5~25℃ customizable)
Temperature uniformity ≤±1℃ (No load)
Humidity fluctuation ±3.0%RH(>75%RH);±5.0%RH(≤75%RH)
Fluttuazione della temperatura ≤±1℃
Humidity accuracy ≤±2.0%RH
Precisione della temperatura ≤±0.1℃
Inner box material SUS304 stainless steel
Outer box material Cold rolled steel plate + plastic spraying
Insulation material Glass fiber cotton & polyurethane
Window size (cm) 30*45
Refrigerante R404A/R23
Test hole φ100mm×1
Riscaldatore Electric heating
Air-cooled condenser Fin heat exchanger
Water-cooled condenser Plate/sleeve/shell and tube heat exchanger
Air circulation Extended shaft motor, stainless steel centrifugal fan blades
Refrigeration method Cascade refrigeration
Compressore Brand variable frequency compressor
Control method Segmented fuzzy PID algorithm control
Communication protocol interface TCP/RS485 (CAN customizable)
Pannello operativo Schermo tattile a colori da 7 pollici, visualizzazione della curva di temperatura
Sensor PT100A grade platinum resistor
Protection device Heater dual temperature protection, refrigeration system protection and electrical overcurrent and overload protection, etc.
Alimentazione 380V±10% 50HZ
Outer box size
 (W*H*D) cm
110*212*175
Execution meets the standard GB/T 2423.1;GB/T 2423.2;GB/T 2423.3;GB/T 2423.4;GB/T 5170.2;GB/T 5170.5;GB/T 11158;GB/T 10589;GB/T 10592; GB/T 10586;IEC 60068-3-5

Inviaci un messaggio sul prodotto
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

  • SUNDI Z Frequency conversion series"      /&gt;<figcaption><span>Air-cooling & Water-coolingConfiguration DetailsWorking PrincipleYou may also be interested in these products               Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only…</span></figcaption></figure></a></div><div class= SUNDI Z Frequency conversion series

    Air-cooling & Water-coolingConfiguration DetailsWorking PrincipleYou may also be interested in these products Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only…

  • SUNDI -10℃~150℃"      /&gt;<figcaption><span>Product data downloadMaterial temperature and equipment outlet temperature control optionalDynamic Cooling Heating SystemControl temperatureTemperature AccuracyConfiguration DetailsWorking PrincipleYou may also be interested in these products   …</span></figcaption></figure></a></div><div class= SUNDI -10℃~150℃

    Product data downloadMaterial temperature and equipment outlet temperature control optionalDynamic Cooling Heating SystemControl temperatureTemperature AccuracyConfiguration DetailsWorking PrincipleYou may also be interested in these products …

  • SUNDI -45℃~300℃"      /&gt;<figcaption><span>ProductDescriptionConfiguration DetailsWorking PrincipleDisplays Various Information:You may also be interested in these products            ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent…</span></figcaption></figure></a></div><div class= SUNDI -45℃~300℃

    ProductDescriptionConfiguration DetailsWorking PrincipleDisplays Various Information:You may also be interested in these products ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent…

  • SUNDI -80℃~250℃"      /&gt;<figcaption><span>Product data downloadProductDescriptionConfiguration DetailsWorking PrincipleYou may also be interested in these products         ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature…</span></figcaption></figure></a></div><div class= SUNDI -80℃~250℃

    Product data downloadProductDescriptionConfiguration DetailsWorking PrincipleYou may also be interested in these products ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature…

caricamento...

已经是到最后一篇内容了!

Espandere di più!