Wuxi Guanya Refrigeration Technology co., ltd
Cryogenic Refrigerator -65℃~-10℃

Cryogenic Refrigerator -65℃~-10℃

  • Cryogenic Refrigerator -65℃~-10℃
  • 冰箱 (5).jpg


  • Product Description
  • Knowledge Center

  • Microcomputer control, cascade temperature controller, digital temperature display, the regulation of unit 0.1℃, inside the temperature range -20 ℃ ~ -125 ℃ adjustable.
  • Multi-safety protection, more reliable operation.
  • France TECUMSEH compressor, Germany DANFOSS compressor, EMERSON compressor, automatic cascade refrigeration technology.
  • With self-diagnosis function, freezer overload protection, high-pressure switches, overload relays, thermal protection device and other security functions, and fully guarantee the use of safety.
  • Three sealed mold layer of insulation, Extra-thick high-density polyurethane foam insulation layer, the effect of good insulation; Inline vacuum insulation panels.
  • Human design, more convenient and flexible.
  • Suitable for mechanical producing plant use.

TECHNICAL PARAMETERS:


Model

GX-6528N

GX-6550N

GX-6580N

GY-6528N

GY-6550N

GY-6580N

GY-65A16N

volume

280L

500L

800L

280L

500L

800L

1600L

Inner dimension

610*600*
760

800*735*
850

1000*800*
1000

800*600*
600

1200*650*
650

1350*800*
750

2000*900*
900

Type

(Vertical)

(Chest/Horizontal)

Capacibility carrying

150KG

220KG

300KG

150KG

220KG

300KG

650KG


Designed bearing capacity is two times of the standard one, (refrigeration system is designed according to the standard capacity when target artifact weight is greater than the standard capacity, the cooling rate will decrease)

Temp. range

-65℃~60℃

-65℃~60℃

-65℃~60℃

-65℃~60℃

-65℃~60℃

-65℃~60℃

-65℃~60℃

Cooling capacity at -60℃

1kw

1.5kw

2.5kw

1kw

1.5kw

2.5kw

4kw

Temp. accuracy

±2℃

±2℃

±2℃

±2℃

±2℃

±2℃

±2℃

Heating power

2kw

3kw

5kw

2kw

3kw

5kw

8kw


Nickel-chromium alloy electric heating heater, the controller has double safety protection, with independent temperature limiter protection.

Cooling rate

(ambient temperature of 25 degrees, no-load, from 60 degrees to -60 degrees about 1 hour).;cooling rate will be a little different for temperature changes.

Controller

ASET multifunctional controller

Operation panel

7-inch color touch screen, display set temperature, measured temperature.

Temp. record

Temperature curve and fault record, U-disk data export, excel format.

Inside circulating air

1650 m³/h

2100 m³/h

2750 m³/h

2100 m³/h

2750 m³/h

3500 m³/h

6000 m³/h


When it is open, the internal circulation fan automatically turns off. The touchscreen displays open state.

Compressor

Emerson Copeland, adopt cascade refrigeration technology

Intermediate heat exchanger

KAORI Plate heat exchanger

Dry filter

Emerson

Expansion valve

Electronic expansion valve

Evaporator

Copper-tube with aluminum-fin

Cooling Type

Air-cooled with water-cooled auxiliary functions (Ensure good cooling capacity when temp. above 30 degrees)

Means of insulation

Polyurethane foam insulation, thermal insulation layer 125 mm, with embedded FIR boards

Safety Protection

Self-diagnosis function; Phase sequence phase failure protection; leakage protector; cooling unit overload protection; high and low pressure switch, overload relay, thermal protection device, high temperature protection and temperature fault protection.

Case material

Outside is cold rolled steel painting, internal is SUS304 wire drawing board.

Refrigerant

R404A R23

Dimension

1150*1150*
1850

1350*1300*
1850

1550*1300*
2100

2200*1150*
1150

2700*1200*
1200

2900*1300*
1250

3700*1400*
1350

Power 380V 50HZ

5.5KW MAX

7.5KW MAX

13.5KW MAX

5.5KW MAX

7.5KW MAX

13.5KW MAX

19KW MAX

Weight

380kg

480kg

650kg

385kg

485kg

650kg

780kg

Optional

High temperature reaches 150degree and temperature accuracy is ±0.5degree;the input power will be changed(When select this model, the thickness of thermal insulation layer will be 150mm,thermal insulation material will be silicate and vacuum plate)

Optional

Closed circulating oil heating system, no direct electric heating element inside the box, suitable for flammable products test

Optional

Temp. accuracy ±0.5℃

Optional

Cooling and heating program controlled, meet cold treatment process requirements(can set 5 programs, each program can edit 45 steps.)

Optional

Interior door, reduce cooling capacity lost when picking small workpieces (temperature below 60 degrees optional)

Optional

Outside SUS304 wire drawing board case

Optional

Diameter 50mm cable hole

Optional

Electric heating vacuum glass observation window (with lighting) 200mm*300mm

Optional

Low temperature automatic defrost (can be once per hour or use manual button to defrost), ensure it can work at low temperature for long time even the door is open and close frequently)


Ultra-low temperature refrigerator is also known as cryopreservation box, cryogenic refrigerator, cryopreservation box and so on, the common low temperature refrigerator of which is -65 ℃ ~ -10℃.

The refrigeration system of ultra-low temperature refrigerator basically adopts the working principle of cascade refrigeration and is equipped with two fully enclosed compressors as high and low temperature compressor. The copper tube of the low-temperature evaporator is attached directly to the outside of the inner box in the form of a coil and with heat transfer cement block between the coil and the box wall of the gap, to increase the heat exchange effect. The condensing evaporator is a shell tube structure with four tubes of the thread-shaped copper tube and a countercurrent heat exchange.

The cryogenic stage system is equipped with a gas heat exchanger to make the low-pressure gas coming out of the evaporator heat exchange with the high-pressure gas before the condenser-evaporator, which not only reduces the heat load of the condensing evaporator but also makes full use of the heat.The wax removal filter is the most common, the main purpose of the filter is to remove the paraffin from the frozen oil in order to reduce the possibility of "oil plugging" in the system.

In addition, according to different applications, ultra-low temperature refrigerator can also be equipped with some accessories. For example, take temperature re
corder for a permanent record of operating parameters; use the carbon dioxide backup system for special circumstances to ensure the gas preservation environment to maintain a normal state and choose the voltage booster for guaranteeing the normal work of the compressor under low pressure.

Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
Leave a Message Email Us

we will contact you within 24 hours.

products
Contact US
Tel: + 86 18751545184
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat