FL-ZD 5℃~30℃
Dual compressor refrigeration unit- Cooling Power61kW~400kW
- Power Supply3N/380V/50Hz
- Weight1650kG~8300kG
Product data download
Product Description
1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.
2.Due to continuous updating of product technology, the above data is subject to change without prior notice.
3.In addition to the listed product models, our company can customize non-standard units according to customer requirements.
Model FL-ZD | 280 | 400 | 500 | 600 | 720 | 840 | 910 | 1008 | 1160 | 1260 | 1340 | 1420 | 1530 | 1700 | 1940 | |
Cooling capacity |
KW | 299 | 426 | 533 | 656 | 786 | 916 | 996 | 1108 | 1267 | 1394 | 1476 | 1557 | 1680 | 1870 | 2134 |
Kcal/hr *10³ |
257 | 366 | 458 | 564 | 677 | 788 | 856 | 953 | 1090 | 1199 | 1269 | 1339 | 1445 | 1608 | 1668 | |
Power | 3N/380V/50Hz | |||||||||||||||
Cooling input power |
KW | 60 | 85 | 107 | 131 | 157 | 183 | 200 | 222 | 253 | 279 | 293 | 311 | 336 | 374 | 427 |
Compressor | Form | semi-closed double screw compressor | ||||||||||||||
Heat control range |
0-25-37.5-50-62.5-75-87.5-100(12.5% segmentation control) | |||||||||||||||
Chilled water |
Form | Dry, overflow or falling film heat exchanger | ||||||||||||||
Chilled water volume T/H |
47 | 67 | 83 | 102 | 123 | 143 | 155 | 173 | 197 | 217 | 230 | 243 | 262 | 291 | 333 | |
Water pressure drop KPa |
44 | 49 | 49 | 50 | 54 | 56 | 58 | 72 | 73 | 73 | 74 | 74 | 75 | 75 | 76 | |
Connection size |
DN80 | DN100 | DN125 | DN150 | DN200 | |||||||||||
Evaporative condenser |
Form | Evaporative condenser system | ||||||||||||||
Security device |
High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc. |
|||||||||||||||
Refrigerant | Charge Kg |
68 | 106 | 136 | 168 | 198 | 242 | 268 | 300 | 330 | 380 | 400 | 410 | 440 | 470 | 500 |
Dimension | Length mm |
3200 | 3235 | 3250 | 3250 | 3810 | 3810 | 3810 | 3830 | 3890 | 3900 | 3900 | 3950 | 3970 | 4870 | 4870 |
Width mm |
945 | 1100 | 1100 | 1300 | 1300 | 1300 | 1300 | 1300 | 1500 | 1500 | 1500 | 1500 | 1500 | 1600 | 1600 | |
Height mm |
1400 | 1420 | 1610 | 1755 | 1950 | 1975 | 1985 | 2050 | 2185 | 2185 | 2200 | 2200 | 2200 | 2250 | 2250 | |
Unit weight |
Kg | 1320 | 1840 | 1920 | 2400 | 2800 | 3040 | 3200 | 3600 | 4560 | 4960 | 5040 | 5360 | 5760 | 6320 | 6640 |
Working weight |
Kg | 1520 | 2040 | 2160 | 2800 | 3200 | 3480 | 3680 | 4040 | 5040 | 5440 | 5520 | 5920 | 6320 | 6880 | 7200 |
You may also be interested in these products
LTZ -115°C~ 90°C
For Pharmaceutical & chemical industrysingle fluid low temperature refrigeration unittemperature controlcooling methodTemperature Control Range-115℃~-80℃Product DescriptionApplicationsrecommend products *Are-cooled and Water-cooled Type…
LN -60°C~ -10°C
Product data downloadPharmaceutical & chemical industrysingle fluid low temperature refrigeration unittemperature controlcooling methodConfiguration DetailsProduct DescriptionWhat is Single machine auto cascade?Local equipmentColor touch scree…
LT -80℃~-20℃
Industrial Air Chiller UnitLOW TEMP. REFRIGERATION CIRCULATORProductDescriptionCooling MethodData Communication InterfaceAPPLICATION SCENARIOProduct ApplicationsRecommend products It can guarantee 24-hour continuous operation …
Hot & Cold Dual Circuit Temp Control Units
Remote control100%helium detection100%safety regulationsFrequency regulationHot and cold dual-channelHot test 80°C~125°℃ For 120°C high temperature heating and dryingCold test -15°c~30°℃ The other side is used for cooling and capturing at 25°CDUAL…
loading…