Ultra Low Temperature Chiller 6kW~180kW
LN-60℃~-10℃- Cooling capacity @-55℃6kW~180kW
- Power range14kW~300kW
- Expansion tank100L~750L
- RefrigerantR404A/R23
- Weight850KG~5600KG
- Place of OriginChina
Product data download
Pharmaceutical & chemical industry
single fluid low temperature refrigeration unit
Fast cooling and low cooling temperature
temperature control
-5~-150°C
cooling method
Water Cooling
Configuration Details
Model | LN-6W | LN-10W | LN-20W | LN-30W | LN-40W | LN-60W | LN-120W | LN-180W |
Temperature Range | -60°C~ -10°C | |||||||
Cooling Capacity At -55°C |
6kw | 10kw | 20kw | 30kw | 40kw | 60kw | 120kw | 180kw |
5160Kcal/h | 8600Kcal/h | 17200Kcal/h | 25800Kcal/h | 344000Kcal/h | 51600Kcal/h | 103200Kcal/h | 154800Kcal/h | |
Circulation Pump Info | 6.6m³/h | 9m³/h | 15m³/h | 25m³/h | 25m³/h | 25m³/h | / | / |
2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | |
Inlet&outlet connection size | DN-25 PN-10 |
DN-32 PN-10 |
DN-40 PN-10 |
DN-40 PN-10 |
DN-50 PN-10 |
DN-50 PN-10 |
DN-65 PN-10 |
DN-80 PN-10 |
Cooling Water at 30 degree | 10m³/h | 14m³/h | 25m³/h | 30m³/h | 35m³/h | 50m³/h | 90m³/h | 120m³/h |
Expansion tank(standard) | 100L | 175L | 350L | 500L | 600L | 750L | / | / |
Compressor | Emerson Scroll compressor,Carlyle;Dorin | Carlyle、HANBELL、Fusheng、Bitzer screw compressor | ||||||
Operation Panel | 7-inch color touch screen display, temperature curve record | |||||||
Control System | PLC&Module,Set temperature difference of refrigeration on & off | |||||||
Closed Circulation System | The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature | |||||||
Circulation Pump | LNEYA Mangetic Pump | |||||||
Evaporator | Plate heat exchanger | |||||||
Condenser | Casing type water-cooled condenser / tube-type water-cooled condenser | |||||||
Intermediate heat exchanger | Plate heat exchanger | |||||||
Refrigeration accessory | Oil separators, drying filters, expansion valves, refrigeration solenoid valves, pressure control, mirrors, etc. all use Emerson / Danfoss and other brands | |||||||
Electric | AC contactors, intermediate relays, circuit breakers, thermal relays, etc. are Schneider / ABB brand | |||||||
Refrigerant | R404A/R23 mixture R508B | |||||||
Secondary refrigerant | No corrosive liquid, ethanol water, heat transfer oil etc. | |||||||
Safety Protection | High pressure protect; water supply cut-off protection; over-current protection; leakage protection; sequential and phase failure protection; High temperature protection; Sensor Failure protection; Liquid low level protection etc. multi-safety protection | |||||||
Level Indicator | Adopt glass liquid level indication | |||||||
Piping material | Expansion tank, cold storage tank and circulation pipeline are all made of SUS304 | |||||||
Case material | Channel steel + square tube + cold rolled plate sealing plate spray 7035 | |||||||
Dimension cm | 100*150*185 | 100*150*185 | 205*145*225 | 250*145*225 | 350*160*245 | 350*160*245 | 500*200*260 | 650*200*260 |
Power | 16kW | 20kW | 36kW | 64kW | 93kW | 122kW | 200kW | 300kW |
dB | within 75dB | within 90 dB | ||||||
Weight (kg) | 850 | 1000 | 1450 | 2000 | 2400 | 3000 | 4200 | 5600 |
Optional | Optional outside touch screen display controller (separated), the communication line distance is 10 meter | |||||||
Optional | Optional explosion-proof touch screen control system (ExdeIIBT4), the communication line distance is 15 meter |
Product Description
1.Temperature ranges from -5℃ ~ -150℃, can meet different temperature
2. Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK. Bitzer, Copeland, Handbell, fusheng; Plate heat exchanger, Small volume, High efficiency
3. Top imported cold controller; Generator cooling water circuit uses intermediate heat exchanger, improve system reliability and safety.
4. DANFOSS electronic expansion valve, high precision control;
5. Adopt Siemens PLC S7-200/300, LNEYA touch screen, automatic control, temperature curve display, temperature record U disk, fault alarm;
6. Offer machine installation and system test, users only need to finish the installation of refrigerant and cooling water.
What is Single machine auto cascade?
Using a single compressor, by means of natural separation and multi-stagesuperposition, the composition and the low boiling point components areoverlapped and the purpose of low temp production is achieved.
Single compressor can realize – 152℃ cooling
Applied to pharmaceutical, biochemical, freeze-drying.and other high-tech industries
Local equipment
Color touch screen
7-inch/10 inch large-sized color touch screen
It can clearly display all information and display real-time temperature changes of the process in the form of curves
Liquid inlet and outlet
Location of inlet and outlet for chilled water and cooling water;
Provide various standard inlet and outlet interface sizes
Liquid inlet and outlet
Location of inlet and outlet for chilled water and cooling water;
Provide various standard inlet and outlet interface sizes
Chiller Knowledge
We know that the low temperature chillers are complicated equipment. Even the switch process, if not according to the standard of operation or with no special maintenance, will inevitably lead to a decline in the refrigeration efficiency of the low temperature chillers and will greatly reduce the service life of the them. Here, we will talk about major attention matters when enterprises use low temperature chillers!
1. Refrigerant leakage
Refrigerant leakage will not only affect the refrigeration efficiency of low temperature chillers, but also affect the health of people in and out of the engine room, so the issue of refrigerant leakage must be noted.
2. Pay attention to the load of the low temperature chillers
The large load of low temperature chillers, or overload phenomenon which is more than the rated load, will bring about serious problems including refrigeration efficiency decline, bigger noise, bigger vibration amplitude, excessive consumption of resources, decline in service life and so on which need to pay attention to!
3. Temperature and pressure
It can be said that the parameters related to temperature and pressure are the most important parameters of low temperature chillers. Enterprises should pay attention to the parameters related to the temperature and pressure of the low temperature chillers, and solve them in time, so as to avoid affecting the normal operation of the low temperature chillers.
Paying attention to the points mentioned above has extraordinary importance for extending the service life of low temperature chillers ,and improving the refrigeration efficiency and the use safety of low temperature chillers.
recommend products
LTZ -115°C~ 90°C
For Pharmaceutical & chemical industrysingle fluid low temperature refrigeration unittemperature controlcooling methodTemperature Control Range-115℃~-80℃Product DescriptionApplicationsrecommend products *Are-cooled and Water-cooled Type…
LJ -45°C~ -10°C
Product data downloadPharmaceutical & chemical industrysingle fluid low temperature refrigeration unittemperature controlcooling methodConfiguration DetailsProduct DescriptionApplicationsREQUEST A QUOTErecommend products …
LD -80°C~ -30°C
Product data downloadConfiguration DetailsProduct DescriptionChiller Knowledgerecommend products 1.Temperature ranges from -5℃ ~ -150℃, can meet different temperature2. Famous brand semi-closed piston compressor, semi-cl…
SLJ -110℃~-150℃
Product data downloadParameters DetailedProduct DescriptionYou may also be interested in these products 1.Temperature ranges from -5℃ ~ -150℃, can meet different temperature2. Famous brand semi-closed piston compress…
loading…
已经是到最后一篇内容了!