Battery Cooling Chiller/Hydrogen Cooling Chiller
KRY -40℃~100℃ 1&1- Heating Power5.5kW~60kW
- Cooling capacity1.2kW~60kW
- Power range10kW~84kW
- Temperature accuracy±0.5℃
- Flow rate output1~40 L/min
- RefrigerantR404A/R507C
- Weight250KG~1300KG
Temperature control in the testing process of new energy vehicle components
Refrigeration, heating, temperature control, flow control
Connect the tested object to a testing platform adapter
The components are cooled and heated internally through ethylene glycol aqueous solution for testing.
-40 ℃~100 ℃ (can be extended to 150 ° C)
Parameters Detailed
Model | Synbol Unit | KRY-455/455W | KRY-475 | KRY-4A10/4A10W | KRY-4A15/4A15W | KRY-4A25/4A25W | KRY-4A38W | KRY-4A60W |
Temp Range | ℃ | -40℃~+100℃ | ||||||
Flow rate output | L/min | 1~10 L/min | 1~25 L/min | 1~25 L/min | 1~40 L/min | 1~40 L/min | 5~50 L/min | 5~50L/min |
Flow rate accuracy | L/min | ±0.2 L/min | ||||||
Heating power | kW | 5.5kW | 7.5kW | 10kW | 10kW/Optional 15kW | 15kW/Optional 25kW | 25kW/Optional 38kW | 38kW/Optional 60kW |
Cooling Capacity | 100℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW |
200℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
0℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
-35℃ | 1.2kW | 1.8kW | 2.5kW | 4kW | 6.5kW | 10kW | 15kW | |
Refrigerant | R404A/ R507C | |||||||
Power 380V50HZ | kW max | 12kW max | 15kW max | 20kW max | 29kW max | 42kW max | 58kW max | 84kW max |
Dimension(W) cm | (W) cm | 55*95*175 | 55*95*175 | 55*95*175 | 70*100*175 | 80*120*185 | 100*150*185 | 145*205*205 |
Dimension(A) cm | (A) cm | 55*95*175 | 55*95*175 | 70*100*175 | 80*120*185 | 100*150*185 | ||
Weight (water cooling) |
KG | 250KG | 280KG | 320KG | 360KG | 620KG | 890KG | 1300KG |
Control Mode | Feedback PID + Our special dynamic control calculation, PLC controller | ||||||||
Temp. control | Process temp. control and jacket temp. control model | ||||||||
Temp. difference | Set or control the temperature difference between jacket oil and raw material process | ||||||||
Program Editor | 10 programs, each program can edit 40 steps | ||||||||
Communication Portocol | MODBUS RTU Protocol, RS485 interface | ||||||||
Material temp. feedback | PT100 OR 4~20mA or communication(normal: PT100) | ||||||||
Temp. feedback | The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor) | ||||||||
Expansion valve | Emerson thermal expansion valve/danfoss thermal expansion valve | ||||||||
Evaporator | DANFOSS/KAORI Plate heat exchanger | ||||||||
Operation Panel | 7-inch touch screen,show temp curve\EXCEL data output | ||||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. | ||||||||
Refrigerant | R404A/R507C/R125/N40 All four refrigerants are available |
Equipment appearance
General equipment
Multichannel equipment
Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently while controlling the temperature, and different customized solutions are required for simultaneous control.
The tested object is attached to a test platform adapter.
The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
The test component needs to go through a specific temperature profile and record changes in temperature.
Temperature variations typically range from -40 ℃to 100 ℃. (expandable to 150 ℃)
When performing a tolerance test, it usually takes an infinite loop.
Multi channel independent temperature control
The system adopts LNEYA PLC control, with simple menu navigation, a 7 inch color large screen, and comprehensive and multifunctional image display of important data information. The newly added safety measures ensure continuous unmanned operation. All relevant operating status data is continuously monitored and visualized on the touch screen. It supports independent control of one to many channels, and each group can be set independently.
Variable frequency regulation
The variable frequency pump can adjust the circulating liquid pressure and flow rate, achieving high-precision control of 5%~100% of the total range adjustment.
Client A
Client B
By using a variable frequency pump, the motor speed can be controlled at the appropriate value corresponding to the required pressure.
The output pressure and flow rate of the circulating liquid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, it can be automatically controlled at the set output pressure through a variable frequency pump. As a result, the power consumption of the pump can be reduced.
Applications
The new energy vehicle component test unit is mainly used for the offline detection of the drivemotor of the new energy vehicle according to relevant test standards and requirements, it cantest and simulate the performance requirements of motor in actual vehicle operation.
Motor and motor controller
Motor coroller durabilitytest, motor and motorcontroller bracket
Charge point test
On load charging experiment and charging communication interactive test
OBC/DC-DC
Model test, power test. Durability test
Power battery system
Battery pack charge and discharge test, fuel cell test
REQUEST A QUOTE
What equipment is needed for battery pack and motor testing?
Cooling Water Chiller:
- Used to control the temperature of the battery pack to ensure that the battery pack can be kept within the specified temperature range during the test.
- Can simulate the performance of the battery pack under different temperature conditions, such as low temperature start-up, high temperature operation, etc.
Heating System:
- When it is necessary to simulate a high temperature environment, the heating system can be used in conjunction with the cooling water circulation machine to ensure that the battery pack can operate under high temperature conditions.
Environmental Simulation Chamber:
- Provides a closed space for simulating different environmental conditions, such as temperature, humidity, air pressure, etc.
- The interior of the environmental simulation box/chamber is usually equipped with monitoring equipment such as temperature sensors and humidity sensors, as well as control equipment such as heaters and humidifiers.
recommend products
KRY 0℃~+100℃ (1to2)
Product data downloadParameters DescriptionProductDescriptionYou may also be interested in these products Temperature range is 0℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature c…
KRY 0℃~+100℃ (1to3)
Product data downloadKRY 0℃~100℃ 1&3S(3 sets of auxiliary temperature control, pressure/flow controlled separately)ProductDescriptionYou may also be interested in these products Test temperature of main test items …
KRY 0℃~+100℃(1&6)
Product data downloadKRY 0℃~100℃ 1&6S(6 sets of auxiliary temperature control, pressure and flow controlled separately)ProductDescriptionWorking PrincipleYou may also be interested in these products Temperatur…