KRY -40℃~100℃ 1&2S
Vehicle antifreeze test temperature simulation- Heating Power10kW~38kW
- Cooling capacity2.5kW~60kW
- Power range17kW~81kW
- Temperature accuracy±0.5℃
- Flow rate output1~40 L/min
- RefrigerantR404A/R507C/R125/N40
- Weight360KG~1750KG
Product data download
Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently while controlling the temperature, and different customized solutions are required for simultaneous control.
The tested object is attached to a test platform adapter.
The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
The test component needs to go through a specific temperature profile and record changes in temperature.
Temperature variations typically range from -40 ℃to 100 ℃. (expandable to 150 ℃)
When performing a tolerance test, it usually takes an infinite loop.
Parameters Detailed
Model | Synbol Unit | KRY-475/475W/2S | KRY-4A15W/2S | KRY-4A25W/2S | KRY-4A38W/2S | KRY-4A60W/2S |
Temp Range | ℃ | -40℃~+100℃ | ||||
Flow rate output | L/min | 1~20 L/min | 1~20 L/min | 1~20 L/min | 1~40 L/min | 1~40 L/min |
Flow rate accuracy | L/min | ±0.2 L/min | ||||
Heating power | kW | 7.5kW | 10kW | 15kW | 25kW | 38kW |
Cooling Capacity | 100℃ | 10kW | 15kW | 25kW | 38kW | 60kW |
200℃ | 10kW | 15kW | 25kW | 38kW | 60kW | |
0℃ | 10kW | 15kW | 25kW | 38kW | 60kW | |
-35℃ | 2.5kW | 4kW | 6.5kW | 10kW | 15kW | |
Refrigerant | R404A/R507C/R125/N40 | |||||
Power 380V50HZ | kW max | 16.5kW | 24kW max | 36kW max | 56kW max | 81kW max |
Dimension(A) cm | (A) cm | 70*100*175 | 80*120*185 | 100*150*185 | 120*180*205 | 145*205*225 |
Weight (water cooling) | KG | 360KG | 450KG | 750KG | 1000KG | 1700KG |
Model | Synbol Unit | KRY-455/455W | KRY-475 | KRY-4A10/4A10W | KRY-4A15/4A15W | KRY-4A25/4A25W | KRY-4A38W | KRY-4A60W |
Temp Range | ℃ | -40℃~+100℃ | ||||||
Flow rate output | L/min | 1~10 L/min | 1~25 L/min | 1~25 L/min | 1~40 L/min | 1~40 L/min | 5~50 L/min | 5~50L/min |
Flow rate accuracy | L/min | ±0.2 L/min | ||||||
Heating power | kW | 5.5kW | 7.5kW | 10kW | 10kW/Optional 15kW | 15kW/Optional 25kW | 25kW/Optional 38kW | 38kW/Optional 60kW |
Cooling Capacity | 100℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW |
200℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
0℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
-35℃ | 1.2kW | 1.8kW | 2.5kW | 4kW | 6.5kW | 10kW | 15kW | |
Refrigerant | R404A/ R507C | |||||||
Power 380V50HZ | kW max | 12kW max | 15kW max | 20kW max | 29kW max | 42kW max | 58kW max | 84kW max |
Dimension(W) cm | (W) cm | 55*95*175 | 55*95*175 | 55*95*175 | 70*100*175 | 80*120*185 | 100*150*185 | 145*205*205 |
Dimension(A) cm | (A) cm | 55*95*175 | 55*95*175 | 70*100*175 | 80*120*185 | 100*150*185 | ||
Weight (water cooling) |
KG | 250KG | 280KG | 320KG | 360KG | 620KG | 890KG | 1300KG |
Control Mode | Feedback PID + Our special dynamic control calculation, PLC controller | ||||||||
Temp. control | Process temp. control and jacket temp. control model | ||||||||
Temp. difference | Set or control the temperature difference between jacket oil and raw material process | ||||||||
Program Editor | 10 programs, each program can edit 40 steps | ||||||||
Communication Portocol | MODBUS RTU Protocol, RS485 interface | ||||||||
Material temp. feedback | PT100 OR 4~20mA or communication(normal: PT100) | ||||||||
Temp. feedback | The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor) | ||||||||
Expansion valve | Emerson thermal expansion valve/danfoss thermal expansion valve | ||||||||
Evaporator | DANFOSS/KAORI Plate heat exchanger | ||||||||
Operation Panel | 7-inch touch screen,show temp curve\EXCEL data output | ||||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. | ||||||||
Refrigerant | R404A/R507C/R125/N40 All four refrigerants are available |
Product Description
For the power battery charging management, the precision temperature control device for testing the permanent magnet synchronous motor, the switched reluctance motor, the asynchronous motor and its controller can realize the local + remote control mode through the liquid crystal controller panel;
With automatic fault protection function, it can output corresponding signals to ensure the safety of equipment. The main parts are all international brands, quality assurance, high-pressure electrostatic spray treatment on the surface, and auxiliary equipment can be added according to specific needs.
You may also be interested in these products
KRY -40℃~+100℃ (1to6)
Product data downloadtemperature control, flow controlParameters DetailedProductDescriptionrecommend products The components are cooled and heated internally through ethylene glycol aqueous solution for testing -40 ° …
KRY -40℃~+100℃ (1to1)
Temperature control in the testing process of new energy vehicle componentsParameters DetailedEquipment appearanceGeneral equipmentMultichannel equipmentMulti channel independent temperature controlVariable frequency regulationClient AClient BAppl…
KRY -40℃~+100℃ (1to3)
Product data downloadKRY -40℃~100℃ 1&3S (3 sets of auxiliary temperature control, Pressure/Flow controlled separately)ProductDescriptionYou may also be interested in these products Dimension(A) cm Temperature r…
loading…