Search the whole station

KRY -40℃~+100℃ (1to3)
KRY -40℃~+100℃ (1to3)
KRY -40℃~+100℃ (1to3)
KRY -40℃~+100℃ (1to3)

KRY -40℃~100℃ 1&3S

Vehicle antifreeze test temperature simulation
  • Heating Power15kW~38kW
  • Cooling capacity4kW~60kW
  • Power range23.5kW~82kW
  • Temperature accuracy±0.5℃
  • Flow rate output1~40 L/min
  • RefrigerantR404A/R507C/R125/N40
  • Weight420KG~1700KG

Product data download

KRY -40℃~100℃ 1&3S (3 sets of auxiliary temperature control, Pressure/Flow controlled separately)

Model Synbol Unit KRY-4A15W/3S KRY-4A25W/3S KRY-4A38W/3S KRY-4A60W/3S KRY-4A25W/6S KRY-4A38W/6S KRY-4A60W/6S
Temp Range  -40℃~+100℃
Flow rate output L/min 1~20 1~20  1~20  1~40  1~20  1~20  1~40 
Flow rate accuracy  L/min ±0.2 L/min
Heating power kW 10kW 15kW 25kW 38kW 15kW 25kW 38kW
Cooling Capacity 100℃ 15kW 25kW 38kW 60kW 25kW 38kW 60kW
200℃ 15kW 25kW 38kW 60kW 25kW 38kW 60kW
0℃ 15kW 25kW 38kW 60kW 25kW 38kW 60kW
 -35℃ 4kW 6.5kW 10kW 15kW 5kW 8kW 13kW
Refrigerant   R404A/R507C/R125/N40
Power 380V50HZ kW max 23.5kW max 36kW max 55kW max 82kW max 38kW max 55kW max 82kW max

Dimension(A) cm

(A) cm 80*120*185 100*150*185 120*180*205 145*205*225 120*180*205 145*205*225 145*205*225
Weight (water cooling) KG 420KG 750KG 1000KG 1700KG 900KG 1200KG 1950KG
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 40 steps
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor)
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C/R125/N40  All four refrigerants are available

Product Description

Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently while controlling the temperature, and different customized solutions are required for simultaneous control.


The tested object is attached to a test platform adapter.
The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
The test component needs to go through a specific temperature profile and record changes in temperature.
Temperature variations typically range from -40 ℃to 100 ℃. (expandable to 150 ℃)
When performing a tolerance test, it usually takes an infinite loop.


Multi-channel temperature flow control, one device can achieve multi-channel output, each channel can control different flows without interference with each other.

Fully closed pipe design, high efficiency plate heat exchanger, used for lifting temperature and constant temperature control in new energy battery and motor test, especially suitable for heat and heat release process control during test.







Send us a message about KRY series Multi-channel chiller
*
*
Submitting…
Submission successful!
Submission failed! Please try again later~
Email error!
Phone error!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

Expand more!