KRY -40℃~100℃ 1&3S
Vehicle antifreeze test temperature simulation- Heating Power15kW~38kW
- Cooling capacity4kW~60kW
- Power range23.5kW~82kW
- Temperature accuracy±0.5℃
- Flow rate output1~40 L/min
- RefrigerantR404A/R507C/R125/N40
- Weight420KG~1700KG
Product data download
KRY -40℃~100℃ 1&3S (3 sets of auxiliary temperature control, Pressure/Flow controlled separately)
Model | Synbol Unit | KRY-4A15W/3S | KRY-4A25W/3S | KRY-4A38W/3S | KRY-4A60W/3S | KRY-4A25W/6S | KRY-4A38W/6S | KRY-4A60W/6S |
Temp Range | ℃ | -40℃~+100℃ | ||||||
Flow rate output | L/min | 1~20 | 1~20 | 1~20 | 1~40 | 1~20 | 1~20 | 1~40 |
Flow rate accuracy | L/min | ±0.2 L/min | ||||||
Heating power | kW | 10kW | 15kW | 25kW | 38kW | 15kW | 25kW | 38kW |
Cooling Capacity | 100℃ | 15kW | 25kW | 38kW | 60kW | 25kW | 38kW | 60kW |
200℃ | 15kW | 25kW | 38kW | 60kW | 25kW | 38kW | 60kW | |
0℃ | 15kW | 25kW | 38kW | 60kW | 25kW | 38kW | 60kW | |
-35℃ | 4kW | 6.5kW | 10kW | 15kW | 5kW | 8kW | 13kW | |
Refrigerant | R404A/R507C/R125/N40 | |||||||
Power 380V50HZ | kW max | 23.5kW max | 36kW max | 55kW max | 82kW max | 38kW max | 55kW max | 82kW max |
Dimension(A) cm |
(A) cm | 80*120*185 | 100*150*185 | 120*180*205 | 145*205*225 | 120*180*205 | 145*205*225 | 145*205*225 |
Weight (water cooling) | KG | 420KG | 750KG | 1000KG | 1700KG | 900KG | 1200KG | 1950KG |
Control Mode | Feedback PID + Our special dynamic control calculation, PLC controller | ||||||||
Temp. control | Process temp. control and jacket temp. control model | ||||||||
Temp. difference | Set or control the temperature difference between jacket oil and raw material process | ||||||||
Program Editor | 10 programs, each program can edit 40 steps | ||||||||
Communication Portocol | MODBUS RTU Protocol, RS485 interface | ||||||||
Material temp. feedback | PT100 OR 4~20mA or communication(normal: PT100) | ||||||||
Temp. feedback | The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor) | ||||||||
Expansion valve | Emerson thermal expansion valve/danfoss thermal expansion valve | ||||||||
Evaporator | DANFOSS/KAORI Plate heat exchanger | ||||||||
Operation Panel | 7-inch touch screen,show temp curve\EXCEL data output | ||||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. | ||||||||
Refrigerant | R404A/R507C/R125/N40 All four refrigerants are available |
Product Description
Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently while controlling the temperature, and different customized solutions are required for simultaneous control.
The tested object is attached to a test platform adapter.
The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
The test component needs to go through a specific temperature profile and record changes in temperature.
Temperature variations typically range from -40 ℃to 100 ℃. (expandable to 150 ℃)
When performing a tolerance test, it usually takes an infinite loop.
Equipped with a powerful circulation pump while ensuring the delivery of highly viscous liquids.
Control the flow output with variable frequency regulation or proportional control valve to achieve high precision control total range 5%~100% adjustment.
Multi-channel temperature flow control, one device can achieve multi-channel output, each channel can control different flows without interference with each other.
Fully closed pipe design, high efficiency plate heat exchanger, used for lifting temperature and constant temperature control in new energy battery and motor test, especially suitable for heat and heat release process control during test.
You may also be interested in these products
KRY -40℃~+100℃ (1to6)
Product data downloadtemperature control, flow controlParameters DetailedProductDescriptionrecommend products The components are cooled and heated internally through ethylene glycol aqueous solution for testing -40 ° …
KRY -40℃~+100℃ (1to1)
Temperature control in the testing process of new energy vehicle componentsParameters DetailedEquipment appearanceGeneral equipmentMultichannel equipmentMulti channel independent temperature controlVariable frequency regulationClient AClient BAppl…
KRY -40℃~+100℃ (1to2)
Product data downloadParameters DetailedProductDescriptionYou may also be interested in these products Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature contro…
loading…
已经是到最后一篇内容了!