TES -60℃~200℃
Cooling Heating System For fuel oil test- Heating Power15kW~60kW
- Cooling capacity3kW~60kW
- Power range28kW~102kW
- Medium accuracy±0.5℃
- fuel oil accuracy±2℃
- RefrigerantR404A/R23
Product data download
The device is used for fueling, lubricating oil cooling or heating when testing fuel, oil and the like for the test bench of Party A.
The heat transfer oil refrigeration heating device provides low temperature or high temperature heat transfer oil, and the heat transfer oil and the fuel oil exchange heat in the inlet heat exchanger of the test piece, so that the fuel can reach the desired temperature condition.
The secondary heat exchange completely solves the problem of temperature resistance of the fuel and oil delivery high pressure pump, and also solves the problem of fuel carbonization and coking caused by the excessive surface temperature of the heater.
LNEYA represents the international advanced liquid temperature control technology, actively explores and studies component testing systems, mainly used for temperature test simulation in semiconductor testing, with wide temperature orientation and high temperature rise and fall, temperature range -92°C ~ 250°C, suitable for various Test Requirements. LNEYA is committed to solving the problem of temperature control lag in electronic components. Ultra high temperature cooling technology can be cooled directly from 300°C.
Parameters Detailed
Model | TES-6A15WPEX TES-6A15WDEX |
TES-6A25WPEX TES-6A25WDEX |
TES-6A45WPEX TES-6A45WDEX |
TES-6A60WPEX TES-6A60WDEX |
|
Temp Range | -60℃~200℃ | -60℃~200℃ | -60℃~200℃ | -60℃~200℃ | |
Heating Power | 15kW | 25kW | 45kW | 60kW | |
Refrigerating Output | 200℃ | 15kW | 25kW | 45kW | 60kW |
100℃ | 15kW | 25kW | 45kW | 60kW | |
20℃ | 15kW | 25kW | 45kW | 60kW | |
0℃ | 15kW | 25kW | 45kW | 60kW | |
-20℃ | 12kW | 20kW | 35kW | 48kW | |
-40℃ | 8kW | 14kW | 25kW | 35kW | |
-50℃ | 5kW | 8kW | 15kW | 25kW | |
-55℃ | 3kW | 5kW | 9kW | 15kW | |
Temp Control Accuracy Of Heat Conduction Medium | ±0.5℃ | ||||
Fuel Temp Control Accuracy | ±2℃ Steady State | ||||
System Pressure Display | Pressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure); | ||||
Pressure of circulatory system is detected by pressure sensor and displayed on touch screen. | |||||
Controller | Siemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm. | ||||
Temperature Control | Temperature Control Mode for outlet of Heat conduction medium; | ||||
External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control). | |||||
Communicating Protocol | Ethernet Interface TCP/IP Protocol | ||||
Internal Temp Feedback | Equipment heat conduction medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, positive pressure chamber ambient temperature, compressor suction temperature, cooling water temperature (water-cooling equipment is configured). | ||||
External Access Temp Feedback | PT100 or 4~20mA or communication given | ||||
Cascade Control Time | The temperature difference between the outlet temperature and the external temperature sensor can be set and controlled; | ||||
TempDifference Control Function | The temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system). | ||||
Closed-cycle System | The whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature. | ||||
Heating Power | The maximum heating output power of the system (according to each model); | ||||
The heater has triple protection and independent temperature limiter to ensure the safety of heating system; | |||||
Heating power 10kW adopts regulator, heating power output control adopts 4~20mA linear control. | |||||
Refrigerating Capacity | Refers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures. | ||||
High Temp Cooling Module | From the high temperature 200 degrees cooling module. | ||||
Circulating pump flow max | Magnetic drive pump | ||||
110L/min 2.5BAR | 200L/min 2.5BAR | 400L/min 2.5BAR | 500L/min 2.5BAR | ||
Source 380V 50HZ | 28kW max | 48kW max | 84kW max | 105kW max | |
Shape Size (Positive Pressure)cm | 135 *145*225 | 150*170*225 | 165*250*225 | 165*250*225 | |
External Dimension (Isolation)mm | 800*1450*1850 | 1000*1750*1850 | 1450*2000*2050 | 1450*2000*2050 | |
Compression Engine | Italy Duling semi-enclosed compressor / BiZell semi-enclosed compressor. | ||||
Evaporator | DANFOSS KAORI Plate Heat Exchanger | ||||
Refrigeration Accessory | Oil separator, dry filter, thermal expansion valve, electronic expansion valve, refrigeration solenoid valve, pressure control, mirror, etc. All adopt Emerson / Danvers brand. | ||||
Operation Panel | Color touch screen, temperature curve display\ EXCEL data export. | ||||
Safe Guarding | With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. | ||||
Cryogen | R-404A R23 | ||||
Interface Size | DN32 PN10 RF | DN32 PN10 RF | DN40 PN10 RF | DN50 PN10 RF | |
Water-Cooled W | Type W is water cooled. | ||||
Water-cooled Condenser | Tube type heat exchanger(Paris/Shenshi). | ||||
Cooling Water Quantity At 32℃ | 5m3/h | 8m3/h | 15m3/h | 20m3/h | |
Shell material | Cold rolled sheet spray (Standard Colour 7035) | ||||
Barotropic Explosion Protection | Positive pressure blast proof (EXPXdmbIICT4) barotropic system must be water-cooled equipment; | ||||
LNEYA explosive proof product installation license number: PCEC-2017-B025 | |||||
Barotropic System Cooling | A constant temperature cooling system is installed inside the barotropic system to ensure that the ambient temperature of the barotropic chamber is below 45℃ | ||||
Navar | LNEYA | ||||
Expansion System | LNEYA | ||||
Intermediate Relay\ Thermal Relay | Intermediate relays, thermal relays, contactors, circuit breakers, etc., all use Schneider and other brands. | ||||
Temperature Sensor | Tiankang | ||||
Explosion-proof Hose | Tu’an explosion-proof threading hose | ||||
Internal&External Control | This\ External control mode is switchable |
Product Description
The device is used for fueling, lubricating oil cooling or heating when testing fuel, oil and the like for the test bench of Party A.
The heat transfer oil refrigeration heating device provides low temperature or high temperature heat transfer oil, and the heat transfer oil and the fuel oil exchange heat in the inlet heat exchanger of the test piece, so that the fuel can reach the desired temperature condition.
The secondary heat exchange completely solves the problem of temperature resistance of the fuel and oil delivery high pressure pump, and also solves the problem of fuel carbonization and coking caused by the excessive surface temperature of the heater.
You may also be interested in these products
MD Series Chuck
Quick temperature change control chuckConfiguration DetailsProduct Description -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…
YQH 0℃~-75℃
Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products Suitable for the recovery of various volatile VOCs gases; Fast c…
FLT-100℃~90℃ low temperature cascade
Product data downloadConfiguration Detailschillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products Model FLTZ-803W FLTZ-805W FLTZ-806W FLT-Z808W FLTZ-810W Temp Range -80℃~+90℃ …
FLTZ -45℃~90℃
Product data downloadTemperature control in semiconductor production and testing processesEnsure stable and reliable overall semiconductor process flow from front-end to back-endProductDescriptionchillers that control the processing temperature on…
loading…
已经是到最后一篇内容了!