Deionized Water Chiller
2℃~20℃- Temperature Control Accuracy±0.5℃
- refrigerantR134A
- Cooling capacity5KW~25KW
Industry temperature control solution
Pure water DI refrigeration unit
PLC control
7-inch screen
100% safety regulations
100% helium detection
Frequency control
Suitable for the production process of 2°℃~5°CDI water demand. Normal temperature Dl water enters the temperature control unit, and the target temperature D1 water is output, which solves the problem of easy freezing of water within 5°C.
Parameters Detailed
Model | LTZ-3DI | LTZ-6DI | LTZ-15WDI | |
LTZ-3WDI | LTZ-6WDI | |||
DI temperature range | 2 ℃~20℃ | 2℃~+20℃ | 2℃~+20℃ | |
Temperature control accuracy | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temperature feedback | Pt100 | Pt100 | Pt100 | |
Cooling capacity 50HZ | 3℃ | 5kW | 10kW | 25kW |
Compressor | Variable frequency compressor | |||
Throttling method | Electronic expansion valve | |||
DI heat exchanger | Plate heat exchanger | |||
Input, Display | 7-inch color touch screen\PLC controller | |||
Communication | Modbus RTU protocol RS485 interface, Ethernet TCP/IP protocol | |||
Safety protection | It has self-diagnosis function; refrigerator overload protection; high and low voltage protection, overload relay, thermal protection device, exhaust and suction temperature protection, sensor fault protection and other safety protection functions. Anti-icing technology. | |||
Refrigerant | R134A | |||
Interface size | G1/2 | G3/4 | G3/4 | |
Water-cooled type @20℃ | 1500L/H | 3000L/H | 4500L/H | |
G1/2 | G3/4 | G3/4 | ||
Water-cooled condenser | The condenser of the water-cooled equipment uses a plate heat exchanger, which requires water supply from a chiller or a closed cooling tower | |||
Air-cooled condenser | Microchannel heat exchanger | Microchannel heat exchanger | Microchannel heat exchanger | |
Power supply | 380V 50HZ can choose three-phase 220V 460V | |||
DI contact pipe material | SUS304 | |||
Casing material | Cold-rolled plate spraying (REL7035) |
DETAIL ADVANTAGE,STRIVING FOR EXCELLENCE
APPEARANCE DETAILS QUALITY CONTROL
REQUEST A QUOTE
Recommended products
Hot & Cold Dual Circuit Temp Control Units
Remote control100%helium detection100%safety regulationsFrequency regulationHot and cold dual-channelHot test 80°C~125°℃ For 120°C high temperature heating and dryingCold test -15°c~30°℃ The other side is used for cooling and capturing at 25°CDUAL…
LTZ Variable frequency M series
recommend products ,
LTG Screw chiller units
LTG series Screw ChillersPLC control7-inch screen100% safety regulations100% helium detectionFrequency controlAll LTG series screw chiller modelsWORKING PRINCIPLE OF REFRIGERATION AND COOLINGDETAIL ADVANTAGE,STRIVING FOR EXCELLENCEWIDE RANGE OFAPP…
DR series Compressed air dryer
Application principleParameters DetailedREQUEST A QUOTERecommended products Additional filtration of oil and particulate matter, the air flow passes through a pre-filter with a filtration grade of 0.01 μm to prevent the desi…
loading…
已经是到最后一篇内容了!