KRY 0℃~100℃ 1&3S
Vehicle antifreeze test temperature simulation- Heating Power5.5kW~60kW
- Cooling capacity11kW~60kW
- Power range22kW~68kW
- Temperature accuracy±0.5℃
- Flow rate output1~40 L/min
- RefrigerantR404A/R507C
- Weight420KG~1700KG
Product data download
KRY 0℃~100℃ 1&3S (3 sets of auxiliary temperature control, pressure/flow controlled separately)
Model | KRY-A15W/3S | KRY-A25W/3S | KRY-A38W/3S | KRY-A60W/3S | |
KRY-A15/3S | KRY-A25/3S | ||||
Temp. Range | 0℃~+100℃ | ||||
Temp. control precision | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. feedback | Pt100 | Pt100 | Pt100 | Pt100 | |
Temp. display | 0.01k | 0.01k | 0.01k | 0.01k | |
Flow control/Group | 2~25 L/min | 2~25 L/min | 2~25 L/min | 1~25 L/min | |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L | ±0.2L | |
Number of fluid output groups | 3 Groups | 3 Groups | 3 Groups | 3 Groups | |
pressure control/Group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
flow pressure description | The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized) | ||||
Heating power | 10kW | 15kW | 25kW | 38kW | |
cooling capacity | 100℃ | 15kW | 25kW | 38kW | 60kW |
20℃ | 15kW | 25kW | 38kW | 60kW | |
5℃ | 11kW | 18kW | 27kW | 42kW | |
compression | Emerson Valley Wheel Compressor | ||||
expansion | Danfoss Thermal Expansion Valve/ Emerson Solenoid | ||||
oil distributor | Emerson | ||||
Dry filter, Pressure | Danfoss | ||||
Evaporator | Plate heat exchanger | ||||
Ciriulating pump | Nangfang centrifugal pump can be selected with imported brand magnetic pump | ||||
Frequency | Delta | ||||
Flow, Pressure sensor | German brand flowmeter, johnson Controls pressure | ||||
input, Display | 7-inch color touch screen \ PLC controller | ||||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | ||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | ||||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | |||||
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available | ||||
Connection size | There are three groups of inlet and outlet,ZG3/4 | ||||
Cooling water at 20C° | 3200L/H | 6000L/H | 9000L/H | 15000L/H | |
Condenser(W) | Shenshi tube type heat exchanger | ||||
Power 380V50HZ | 22kW | 33kW | 45kW | 68kW | |
Dimension cm | 80*120*185 | 100*150*185 | 100*150*185 | 100*150*185 | |
Weight | 420kg | 750kg | 1000kg | 1700kg | |
Optional | 220V 60HZ three phase 460V 60H three phase | ||||
Optional | The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, | ||||
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp. | |||||
Optional | When the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving |
Product Description
Test temperature of main test items of vehicle electronics:
IC test conditions for locomotives: -40℃~125℃, wind blowing, sun exposure, high vibration;
Instrument panel operation test test conditions: -40℃~85℃;
Motor controller test conditions: operating test temperature: 40 ℃ ~ 110 ℃;
Satellite positioning (GPS) Test conditions: high temperature operation test temperature: 85℃; low temperature operation test temperature: -40℃;
Compound vibration: -40℃~80℃;
Obviously the best solution is for the test house to have temperature simulation system equipment.
You may also be interested in these products
KRY 0℃~+100℃ (1to2)
Product data downloadParameters DescriptionProductDescriptionYou may also be interested in these products Temperature range is 0℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature c…
KRY 0℃~+100℃(1&6)
Product data downloadKRY 0℃~100℃ 1&6S(6 sets of auxiliary temperature control, pressure and flow controlled separately)ProductDescriptionWorking PrincipleYou may also be interested in these products Temperatur…
KRY 0℃~+100℃ (1to1)
Product data downloadParameters DetailedProductDescriptionWorking PrincipleYou may also be interested in these products Temperature range is 0℃~+100℃, which can be extended to +135℃ according to the actual situation, and the tem…
loading…
已经是到最后一篇内容了!