FL-ZS 5℃~30℃
Single compressor refrigeration unit- Cooling Power18kW~213kW
- Power Supply3N/380V/50Hz
- Weight850kG~4345kG
Product data download
Product Description
1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.
2.Due to continuous updating of product technology, the above data is subject to change without prior notice.
3.In addition to the listed product models, our company can customize non-standard units according to customer requirements.
Model FL-ZS | 90 | 100 | 140 | 180 | 200 | 250 | 300 | 350 | 400 | 460 | 510 | 600 | 660 | 750 | 850 | 940 | |
Cooling capacity |
KW | 107 | 119 | 149 | 174 | 214 | 273 | 326 | 383 | 426 | 504 | 556 | 646 | 723 | 819 | 933 | 1027 |
Kcal/hr *10³ |
92 | 102 | 128 | 150 | 184 | 235 | 280 | 329 | 366 | 433 | 478 | 555 | 621 | 704 | 802 | 883 | |
Power | 3N/380V/50Hz | ||||||||||||||||
Cooling input power |
KW | 22 | 24 | 30 | 35 | 43 | 55 | 65 | 77 | 85 | 101 | 111 | 130 | 145 | 164 | 187 | 206 |
Compressor | Form | semi-closed double screw compressor | |||||||||||||||
Heat control range |
0-25-37.5-50-62.5-75-87.5-100(12.5% segmentation control) | ||||||||||||||||
Chilled water |
Form | Dry, overflow or falling film heat exchanger | |||||||||||||||
Chilled water volume T/H |
15.5 | 18 | 23 | 27 | 33 | 42 | 51 | 60 | 67 | 79 | 87 | 101 | 113 | 128 | 146 | 160 | |
Water pressure drop KPa |
49 | 60 | 73 | ||||||||||||||
Connection size |
DN65 | DN80 | DN100 | DN125 | DN150 | ||||||||||||
Evaporative condenser |
Form | Evaporative condenser system | |||||||||||||||
Security device |
High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc. | ||||||||||||||||
Refrigerant | Charge Kg |
40 | 46 | 60 | 70 | 88 | 96 | 110 | 116 | 122 | 150 | 170 | 180 | 230 | 266 | 310 | 330 |
Dimension | Length mm |
2500 | 2500 | 2585 | 2635 | 2635 | 3100 | 3130 | 3130 | 3135 | 3135 | 3135 | 3135 | 3275 | 3300 | 3300 | 3668 |
Width mm |
850 | 850 | 900 | 900 | 900 | 900 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |
Height mm |
1100 | 1100 | 1135 | 1135 | 1128 | 1128 | 1270 | 1380 | 1476 | 1400 | 1400 | 1600 | 1620 | 1670 | 1700 | 1720 | |
Unit weight |
Kg | 680 | 680 | 680 | 840 | 1016 | 1144 | 1392 | 1480 | 1984 | 2080 | 2296 | 2560 | 2720 | 2880 | 3080 | 3476 |
Working weight |
Kg | 720 | 720 | 720 | 880 | 1136 | 1264 | 1512 | 1640 | 2064 | 2240 | 2496 | 2800 | 2960 | 3120 | 3320 | 3712 |
You may also be interested in these products
LTZ -115°C~ 90°C
For Pharmaceutical & chemical industrysingle fluid low temperature refrigeration unittemperature controlcooling methodTemperature Control Range-115℃~-80℃Product DescriptionApplicationsrecommend products *Are-cooled and Water-cooled Type…
LN -60°C~ -10°C
Product data downloadPharmaceutical & chemical industrysingle fluid low temperature refrigeration unittemperature controlcooling methodConfiguration DetailsProduct DescriptionWhat is Single machine auto cascade?Local equipmentColor touch scree…
LT -80℃~-20℃
Industrial Air Chiller UnitLOW TEMP. REFRIGERATION CIRCULATORProductDescriptionCooling MethodData Communication InterfaceAPPLICATION SCENARIOProduct ApplicationsRecommend products It can guarantee 24-hour continuous operation …
Hot & Cold Dual Circuit Temp Control Units
Remote control100%helium detection100%safety regulationsFrequency regulationHot and cold dual-channelHot test 80°C~125°℃ For 120°C high temperature heating and dryingCold test -15°c~30°℃ The other side is used for cooling and capturing at 25°CDUAL…
loading…
已经是到最后一篇内容了!