LC-ZS -25℃~5℃
-25℃ evaporative condenser single compressor chiller- Cooling Power24kW~214kW
- Power Supply3N/380V/50Hz
- Weight680kG~3476kG
Product Description
1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.
2.Due to continuous updating of product technology, the above data is subject to change without prior notice.
3.In addition to the listed product models, our company can customize non-standard units according to customer requirements.
Model LC-ZS | 100 | 140 | 180 | 200 | 260 | 300 | 340 | 410 | 470 | 510 | 620 | 710 | 790 | 830 | 930 | |
Cooling capacity |
KW | 51 | 68 | 89 | 98 | 132 | 152 | 176 | 210 | 250 | 263 | 325 | 377 | 415 | 445 | 497 |
-15℃ | Kcal/hr *10³ |
44 | 58 | 77 | 84 | 114 | 131 | 151 | 181 | 215 | 226 | 280 | 324 | 357 | 383 | 427 |
Cooling capacity -20℃ |
KW | 42 | 56 | 73 | 80 | 108 | 125 | 145 | 172 | 205 | 216 | 266 | 310 | 340 | 365 | 408 |
Kcal/hr *10³ |
36 | 48 | 63 | 69 | 93 | 108 | 125 | 148 | 176 | 186 | 228 | 267 | 292 | 314 | 351 | |
Power | ||||||||||||||||
Cooling input power |
KW | 24 | 32 | 40 | 45 | 60 | 68 | 77 | 93 | 110 | 116 | 142 | 164 | 183 | 195 | 214 |
Compressor | Form | semi-closed double screw compressor | ||||||||||||||
Heat control range |
0~25~37.5~50~62.5~75~87.5~100(12.5% segmentation control) | |||||||||||||||
Chilled water |
Form | Dry, overflow or falling film heat exchanger | ||||||||||||||
Chilled water volume T/H |
18 | 23 | 27 | 33 | 42 | 51 | 60 | 67 | 79 | 87 | 101 | 113 | 128 | 146 | 160 | |
Water pressure drop KPa |
49 | 60 | 73 | |||||||||||||
Connection size |
DN65 | DN80 | DN100 | DN125 | DN150 | |||||||||||
Evaporative condenser |
Form | Evaporative condenser system | ||||||||||||||
Security device |
High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc. |
|||||||||||||||
Refrigerant | Charge Kg |
46 | 60 | 70 | 88 | 96 | 110 | 116 | 122 | 150 | 170 | 180 | 230 | 266 | 310 | 330 |
Dimension | Length mm |
2500 | 2585 | 2635 | 2635 | 3100 | 3130 | 3130 | 3135 | 3135 | 3135 | 3135 | 3275 | 3300 | 3300 | 3668 |
Width mm |
850 | 900 | 900 | 900 | 900 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |
Height mm |
1100 | 1135 | 1135 | 1128 | 1128 | 1270 | 1380 | 1476 | 1400 | 1400 | 1600 | 1620 | 1670 | 1700 | 1720 | |
Unit weight |
Kg | 680 | 680 | 840 | 1016 | 1144 | 1392 | 1480 | 1984 | 2080 | 2296 | 2560 | 2720 | 2880 | 3080 | 3476 |
Working weight |
Kg | 720 | 720 | 880 | 1136 | 1264 | 1512 | 1640 | 2064 | 2240 | 2496 | 2800 | 2960 | 3120 | 3320 | 3712 |
You may also be interested in these products
LTZ -115°C~ 90°C
For Pharmaceutical & chemical industrysingle fluid low temperature refrigeration unittemperature controlcooling methodTemperature Control Range-115℃~-80℃Product DescriptionApplicationsrecommend products *Are-cooled and Water-cooled Type…
LN -60°C~ -10°C
Product data downloadPharmaceutical & chemical industrysingle fluid low temperature refrigeration unittemperature controlcooling methodConfiguration DetailsProduct DescriptionWhat is Single machine auto cascade?Local equipmentColor touch scree…
LT -80℃~-20℃
Industrial Air Chiller UnitLOW TEMP. REFRIGERATION CIRCULATORProductDescriptionCooling MethodData Communication InterfaceAPPLICATION SCENARIOProduct ApplicationsRecommend products It can guarantee 24-hour continuous operation …
Hot & Cold Dual Circuit Temp Control Units
Remote control100%helium detection100%safety regulationsFrequency regulationHot and cold dual-channelHot test 80°C~125°℃ For 120°C high temperature heating and dryingCold test -15°c~30°℃ The other side is used for cooling and capturing at 25°CDUAL…
loading…